电池支架地震载荷测试认证IEEE Std 693
电池支架地震载荷测试认证IEEE Std 693
产品价格:¥100000(人民币)
  • 规格:完善
  • 发货地:全国全国
  • 品牌:
  • 最小起订量:1个
  • 免费会员
    会员级别:试用会员
    认证类型:企业认证
    企业证件:通过认证

    商铺名称:上海西测检测技术有限公司

    联系人:朱逸(先生)

    联系手机:

    固定电话:

    企业邮箱:jason.zhu@sicecert.cn

    联系地址:蕰川路512号6D

    邮编:201901

    联系我时,请说是在汽配名企网上看到的,谢谢!

    商品详情

      IEEE Std 693-2005 IEEE Power Engineering Society Sponsored by the Substations Committee


      通过SICE认证进行的技术检查发现整个结构中是否存在任何损坏的零件或变形,并验证其安全性,从而确保了风险的显着降低和更安全的仓库运营。

      由于反复发生地震,重要的是要根据UNI / TS 11379标准“金属搁板。设计用于地震载荷下的静态托盘存放的架子”,以通过FEM分析来验证现有货架是否是最新的,并在必要时建议采取适当的措施。
      此外,附件四第1.1.3点。 《统一安全法》(第81/08号法律)规定了表明用于存储的工作场所中最大允许负荷的义务。具体来说,UNI EN 15635规范“钢静态存储系统。存储设备的使用和维护”要求存储设备的用户要求合格的专家对设备进行年度检查。
      监管参考
      EN 15635和支腿。 Dec. 81/08定期检查保护状态。
      EN 15512和Eurocode 3对现有搁板的抵抗性检查。
      EN 15512验证新货架的正确尺寸。
      EN 15620和EN 15635在组装结束时验证新的搁板。

      UNI / TS 11379在地震载荷下的金属搁板设计。

      IEEE Std 693-2005 IEEE Power Engineering Society Sponsored by the Substations Committee

      2015 International Building Code – IBC 2015
      2016 California Building Code – CBC 2016
      These battery racks are hereby seismically qualified when properly installed for their structural adequacy in areas with the Risk-Targeted Maximum Considered Earthquake (MCER) Design Spectral Acceleration Parameter at a short period of SDS ≤ 0.88g as defined by the above codes. These battery
      racks shall be located at or below grade with z/h=0. These battery Racks shall be used with Risk Categories I, II & III, on Site Classes A, B, C & D, and in structures assigned with Seismic Design Categories A, B, C, D & E. Other limitations and modifications of this qualification are included in our
      seismic qualification report dated April 23, 2014. This qualification is based on a thorough review of the
      report entitled “static calculations of racks for earthquake battery installation” produced by:
      Kühne BSB GmbH, Mina-Rees-Stra?e 5A, 64295 Darmstadt - Deutschland

    在线询盘/留言
  • 0571-87774297