详细介绍:
095U3D300BACAA100190 电机驱动Part number Descrtption
116-AUTROMASTER-PC-11 PC , desktop version, convertible minitower. Model subject to change without prior notice.
116-AUTROMASTER-RACKPC 19" rack mounted PC
116-5151-020.0210 Industrial PC w/SSD
116-5151-020.1951 19" standard LCD monitor (1280 x 1024 resolution)
116-5151-020.2405 24" widescreen LCD monitor (1920 x 1200 resolution)
116-5151-200.0023 20” monitor, console mounted, JH20T17 MMD
116-5151-017.0002 Keyboard - UK/English character set
116-5151-020.0400 Mouse - USB - 3 buttons
116-5760-050.2003 Laser printer, colour, network and USB
116-5151-020.0732 Network card TG-3468 10/100/1000
116-5151-020.2029 Moxa 4-port serial PCIE
26 Autronica Fire and Security AS, Petrochemical, Oil & Gas 27
PRODUCTS 2016
Loop units
Input and output units
Input and output units
AutroSafe offers a wide range of input and output units for many different applications. The system features Exn-, Exia- and Exd approved input and output units for
high risk applications. All input and output units feature automatic addressing and short-circuit protection.
Image Part number Descrtption
Configurable input
Monitored input
Monitored output
Inputs/outputs
Requires external PSU
SelfVerify
For use in EX areas
SIL2*
Ingress Protection
level**
Notes
116-BN-180 AutroKeeper ? IP30
Use two units to access
one loop from two loop
controllers.
DIN rail mounting in
cabinet.
116-BN-201 Monitoring unit ? ? 1/0 ?
IP54
IP67
For external units
116-BN-221/01
Extinguishing control
unit
? ? 2/1 ? ? IP67
116-BN-221/02
Output unit with
7 A relay
? 0/1 ? ? IP67 Loop controlled FAD unit
116-BN-300 Input unit ? ? 1/0 ? ?
IP54
IP67
For interfacing external
units, clean contacts,
alarm relays, etc.
116-BN-300M Modular input unit ? ? 1/0 ? ? Mounting on TS-35 rail
*: SIL 2 certified as part of AutroSafe system SIL 2 certificate.
**: When two degrees of protection is given, the lowest is relevant when using the included glands. To achieve the highest, special IP67 glands must be
ordered (see page 43)
We provide a wide range of loop units for our fire detection systems. Our
detectors, manual call points, I/O units, control units and alarm units are
developed and approved according to European directives (CPD) requiring
EN 54 compliance and other appropriate worldwide regulations.
The loop units are available both with and without SelfVerify function.
SelfVerify solves all issues of manual maintenance, leaving time consuming
and costly physical testing redundant. With AutroSafe SelfVerify?, the
system checks all detectors, interfaces, connections and cables – from
detector chamber to alarm output – every single day.
Not only does the system test whether a detector is capable of provoking
an alarm, it even verifies the sensitivity of every detector with a calibrated
signal. The SelfVerify system ensures that each detector always responds
to the correct alarm level. In the event of irregularities, the display on the
operating panel will accurately pinpoint the source of any problem.
SelfVerify ensures that you have the safest and most reliable fire safety
system available – a system ensuring optimal detection.
Loop units
A wide range covering your basic fire detection needs
SelfVerify ensures
optimal detection
28 Autronica Fire and Security AS, Petrochemical, Oil & Gas 29
PRODUCTS 2016
Loop units
Input and output units
Input and output units (cont.)
Image Part number Descrtption
Configurable input
Monitored input
Monitored output
Inputs/outputs
Requires external PSU
SelfVerify
For use in EX areas
SIL 2*
Ingress Protection level**
Notes
116-BN-303
Single monitored
input unit
? ? 1/0 ?
IP54
IP67
Function selectable
via dip switch
Limited approvals
(Not SIL2/FM/USCG)
116-BN-304 Input/output unit ? ? ? 1/1 ?
IP54
IP67
Function selectable
via dip switch
Limited approvals
(Not SIL2/FM/USCG)
116-BN-305
Dual monitored input/
output unit
? ? ? 2/2 ?
IP54
IP67
Function selectable
via dip switch
Limited approvals (Not
SIL2/FM/USCG)
116-BN-307
Monitored Fire Alarm
Device Control Unit
? 0/1 ? ?
IP54
IP67
Limited approvals (Not
SIL2/FM/USCG)
116-BN-310 Relay output unit 0/1 ? ?
IP54
IP67
116-BN-320 Interface unit ? ? 2/1 ? ?
IP54
IP67
*: SIL 2 certified as part of AutroSafe system SIL 2 certificate.
**: When two degrees of protection is given, the lowest is relevant when using the included glands. To achieve the highest, special IP67 glands must be
ordered (see page 43)
Input and output units (cont.)
Image Part number Descrtption
Configurable input
Monitored input
Monitored output
Inputs/outputs
Requires external PSU
SelfVerify
For use in EX areas
SIL 2*
Ingress Protection level**
Notes
116-BN-320/2 Door control unit ? 2/1 ? ?
IP54
IP67
116-BN-320/4 Standard control unit ? 2/1 ? ?
IP54
IP67
Control of external equipment
116-BN-320/5
Sprinkler monitoring
unit
? 1/0 ? ?
IP54
IP67
116-BNB-330A
Loop adapter unit for
conventional loops
? 1/1 ? ? IP20
Replacement unit for BNB-
330 in existing AutroSafe 3
systems
116-BNB-331
Loop adapter unit for
conventional loops
? 1/1 ? ? IP20 AutroSafe ver. 4.4.1 ?
116-BN-500/EX Input unit ? ? 1/0 ? ? ?
IP54
IP67
For interfacing external units,
clean contacts, alarm relays,
etc.
Zones 0, 1 & 2
*: SIL 2 certified as part of AutroSafe system SIL 2 certificate.
**: When two degrees of protection is given, the lowest is relevant when using the included glands. To achieve the highest, special IP67 glands must be
ordered (see page 43)
30 Autronica Fire and Security AS, Petrochemical, Oil & Gas 31
PRODUCTS 2016
Loop units
Control units
Input and output units (cont.)
Image Part number Descrtption
Configurable input
Monitored input
Monitored output
Inputs/outputs
Requires external PSU
SelfVerify
For use in EX areas
SIL 2*
Ingress Protection level**
Notes
116-BN-500/N Input unit ? ? 1/0 ? ?
IP54
IP67
For interfacing external
units, clean contacts,
alarm relays, etc.
Zone 2
116-BN-505/EXD
Input unit with BNB-
300
? ? 1/0 ? ? IP66 Zones 1 & 2 only
*: SIL 2 certified as part of AutroSafe system SIL 2 certificate.
**: When two degrees of protection is given, the lowest is relevant when using the included glands. To achieve the highest, special IP67 glands must be
ordered (see page 43)
Control units
AutroSafe offers control units for enabling and disabling of detectors, as well as daytime/nighttime units. Available in several language versions. Replace
XX with country code.
Image Part number Descrtption
Number of buttons
For external control
Configurable delay
For AutroSafe only
Ingress Protection level
Notes
116-BW-200/XX Disablement unit 2 ? IP66 Available in Swedish, English and Russian
116-BW-201/XX Disablement unit 0 ? ? IP66 Available in Swedish and English
116-BW-202/XX
Daytime/Nighttime
unit
2 ? ? IP66
Up to two units can be powered from detector
loop. To connect more units, external 24 VDC
power is required.
Available in English only.
116-BW-203/XX
Daytime/Nighttime
unit
0 ? ? IP66
Up to two units can be powered from detector
loop. To connect more units, external 24 VDC
power is required.
Available in English only.
116-BU-200 Alarm controller unit 2 ? IP66
32 Autronica Fire and Security AS, Petrochemical, Oil & Gas 33
PRODUCTS 2016
Loop units
Detectors
Detectors
AutroSafe offers a wide range of detectors for many different applications, with or without SelfVerify. The following series are available:
? 200 series, standard interactive addressable detectors
? 300 series with SelfVerify, interactive addressable detectors
? 500 series with SelfVerify, interactive addressable detectors for use in hazardous areas
The system also offers Exn- and Exia approved versions of detectors designed for use in high risk applications. S series smoke detectors are specially
designed for applications where high sensitivity is required.
Image Part number
Heat
Smoke
MultiSensor
SelfVerify
Including base
Environmentally protected
For use in EX areas
For use in EX zone 2 only
High sensitivity
Sealed unit
SIL 2 certified
Ingress Protection level
Notes
116-BD-200M ? ? ? ? IP56
For galleys/cold areas
(-30 oC)
116-BD-501 ? ? ? ? ? ? IP56
116-BD-501/EX ? ? ? ? ? ? ? IP56
116-BD-501/N ? ? ? ? ? ? ? IP56
116-BD-55/XXXEXD ? ? ? ? IP66/67
*
Conventional
116-BD-55/XXXEXDN ? ? ? ? IP66/67
**
Conventional
116-BD-505/140EXD ? ? ? ? ? IP66
60 oC, non-configurable class,
explosion proof
116-BD-505/160EXD ? ? ? ? ? IP66
70 oC, non-configurable class,
explosion proof
116-BD-505/190EXD ? ? ? ? ? IP66
90 oC, non-configurable class,
explosion proof
*: Available with the following alarm temperatures (replace XXX with °F): 140 °F (60 °C), 160 °F (70 °C), 190 °F (90 °C), 225 °F (110 °C),
325 °F (165 °C), 360 °F (180 °C), and 450 °F (230 °C)
**: Available with the following alarm temperatures (replace XXX with °F): 225 °F (110 °C), 275 °F (135 °C), 325 °F (165 °C), 360 °F (180 °C),
and 450 °F (230 °C)
Image Part number
Heat
Smoke
MultiSensor
SelfVerify
Including base
Environmentally protected
For use in EX areas
For use in EX zone 2 only
High sensitivity
Sealed unit
SIL 2 certified
Ingress Protection level
Notes
116-BDH-300 ? ? ? IP44D
116-BDH-500 ? ? ? ? IP44D
116-BDH-500/EX ? ? ? ? ? IP44D
116-BDH-500/N ? ? ? ? IP44D
116-BHH-300 ? ? ? IP44D
116-BHH-500 ? ? ? ? IP44D
116-BHH-500/EX ? ? ? ? ? IP44D
116-BHH-500/N ? ? ? ? ? IP44D
116-BHH-500/S ? ? ? ? ? IP44D
116-BHH-500/S/EX ? ? ? ? ? ? IP44D
116-BHH-500/S/N ? ? ? ? ? ? IP44D
116-BHH-320 ? ? ? IP44D
116-BHH-520 ? ? ? ? IP44D
116-BHH-520/EX ? ? ? ? ? IP44D
116-BHH-520/N ? ? ? ? ? IP44D
116-5815-021.0001 ? ? ? IP54
Thermostat ATHF-SE-2, 20-150°C
For use in Safe Area or Ex zone 2
Suitable for use in sauna
116-5861-033.0150 ? ? ? ? IP65 SWM-1KL 140°C
34 Autronica Fire and Security AS, Petrochemical, Oil & Gas 35
PRODUCTS 2016
Loop units
Manual call points and release stations
Manual call points and release stations
AutroSafe offers a wide range of manual call points for different applications, every unit features SelfVerify.
Two main series are available:
? 300 series with SelfVerify, interactive addressable manual call points.
? 500 series with SelfVerify, interactive addressable manual call points for use in special environments.
The system features Exn- and Exia approved versions for high risk applications.
All our manual call points can be delivered with a double-action cover.
Image Part number Descrtption
For use in EX areas
For use in EX zone 2 only
Watertight / outdoor model
Extreme environments
LED indicator
Metal connection box
Glass NOT included
Optional duty label*
Ingress Protection level*
116-BF-300V2 Manual call point ? IP42D*
116-BF-510WP-H Manual call point ? ? ? IP52*
116-BF-500V2/EX Manual call point ? IP44D*
New design 2016 116-BF-500/N Manual call point ? ? IP44D*
116-BF-501 Manual call point ? ? IP66
116-BF-501/EX Manual call point ? ? ? IP66
116-BF-501/N Manual call point ? ? ? IP66
*: Ingress Protection level, inner housing
Manual call points and release stations (cont.)
Image Part number Descrtption
For use in EX areas
Zone 2 only
Watertight / outdoor model
Extreme environments
LED indicator
Metal connection box
Glass NOT included
Optional duty label*
Degree of
protection
116-BF-502 Manual call point ? ? IP66
116-BF-502/EX Manual call point ? ? ? IP66
116-BF-502/N Manual call point ? ? ? IP66
116-BF-503/EX/0100 Manual call point ? ? ? N/A IP66
116-BF-503/N/0100 Manual call point ? ? ? N/A IP66
116-KIT-BF-503/EX/0300 Release station ? ? ? N/A ? IP66
116-KIT-BF-503/N/0300 Release station ? ? ? N/A ? IP66
116-KIT-BF-503/0400 Release station ? ? N/A ? IP66
116-KIT-BF-503/EX/0400 Release station ? ? ? N/A ? IP66
116-KIT-BF-503/N/0400 Release station ? ? ? N/A ? IP66
116-KIT-BF-503/0500 Release station ? ? N/A ? IP66
116-KIT-BF-503/EX/0500 Release station ? ? ? N/A ? IP66
116-KIT-BF-503/N/0500 Release station ? ? ? N/A ? IP66
116-BFG-3/XX
Glass for call point, available in several languages. Replace XX with country code.
No ending = No text
GB = English
GB/AR = English and Arabic
N/GB = Norwegian and English
SU = Russian
36 Autronica Fire and Security AS, Petrochemical, Oil & Gas 37
PRODUCTS 2016
Loop units
Alarm units
*Duty lables
Part number Text Part number Text
116-E-2327/1 Inergen utl?sning | Inergen Release 116-E-2327/26 CO2 Release station
116-E-2327/2 Brannmelder | Fire alarm 116-E-2327/27 CO2 Inhibit station
116-E-2327/3 Water release 116-E-2773/1 Abandon ship
116-E-2327/4 Fire | Brann 116-E-2773/2 Abandon
116-E-2327/5 Vannutl?sning | Water release 116-E-2773/3 Gass | Gas
116-E-2327/6 Inergen press. | Release 116-E-2773/4 Vannt?ke
116-E-2327/7 Vannutl?ser | Water release 116-E-2773/5 ESD 2
116-E-2327/8 Fire Monitor | Water release 116-E-2773/6 CO2 release & inhibit station
116-E-2327/9 Deluge | Water release 116-E-2773/7 VEEUDU K?IVITAMINE
116-E-2327/10 Deluge release 116-E-2773/8 Argonite
116-E-2327/11 Vannt?ke | Water mist 116-E-2773/9 General emergency alarm
116-E-2327/12 Alarm 116-E-2773/10 Argonite Release
116-E-2327/13 Overrisling | Deluge 116-E-2773/11 ESD
116-E-2327/14 Start fire pumps | Старт пожарный насос 116-E-2773/12 Electrical isolation
116-E-2327/15 Vannt?ke | Utl?sning 116-E-2773/13 MCP | Ручной извещатель
116-E-2327/16 Overrisling 116-E-2773/14 ESD AB. OCT.
116-E-2327/17 Fire Push button 116-E-2773/15 CO2 Manual station abort
116-E-2327/18 General Alarm 116-E-2773/16 CO2 Manual station release
116-E-2327/19 FM200 release 116-E-2773/17 Manual alarm call point
116-E-2327/20 FM200 inhibit 116-E-2773/18 Exstinguishant release pushbutton
116-E-2327/21 Fire 116-E-2773/19 East monitor actuation
116-E-2327/22 Water mist release 116-E-2773/20 West monitor actuation
116-E-2327/23 Start Firewater pump 116-E-2773/21 Foam system release
116-E-2327/24 Start Foam skid 116-E-2773/22 Vannutl?ser | Deluge release
116-E-2327/25 Clean Agent release
MEDC manual call points and release stations
Autronica Fire and Security AS distribute MEDC equipment. Please contact us with your request.
These products are produced according to customer specifications.
Alarm units
AutroSafe offers a wide range of alarm units for connection to detection loops or dedicated alarm outputs.
Image Part number Descrtption
Loop mounted/addressable
Alarm output mounted
Electronic
Signal presets
Configurable
Watertight
Sound
Light
Sound output (dBA/1 m)
Light output (c/j)*
Ingress Protection level
Notes
116-BBL-100 Alarm indicator ? ? - 2 c IP32C
Supported only
by AutroSafe
version 4.3 or
later
116-BBL-100/IP Alarm indicator ? ? ? - 2 c IP66
Supported only
by AutroSafe
version 4.3 or
later
116-BBR-7M Alarm bell 6” ? ? 93 – IP55
116-BBR-130
Combined
detector base
and addressable
sounder.
? ? ? 90 – IP32C
Supported only
by AutroSafe
version 4.3 or
later
116-BBR-230 Sounder ? ? ? 100 – IP32C
Supported only
by AutroSafe
version 4.3 or
later
*: Candela (c), Joule (j)
**: If loop driver BSD-311 is used, max. no. of units per loop is 40
If loop driver BSD-310 is used, max. no. of units per loop is 21
38 Autronica Fire and Security AS, Petrochemical, Oil & Gas 39
PRODUCTS 2016
Loop units
Alarm units
Alarm units (cont.)
Image Part number Descrtption
Loop mounted/addressable
Alarm output mounted
Electronic
Signal presets
Configurable
Watertight
Sound
Light
Sound output (dBA/1 m)
Light output (c/j)*
Ingress Protection level
Notes
116-BBR-230/IP Sounder ? ? ? ? 100 – IP65
Supported only
by AutroSafe
version 4.3 or
later
116-BBQ-130
Base sounder w/
alarm indicator
? ? ? ? 90 2 c IP21C
Supported only
by AutroSafe
version 4.3 or
later
116-BBQ-230
Sounder/alarm
indicator
? ? ? ? 100 2 c IP32C
Supported only
by AutroSafe
version 4.3 or
later
116-BBQ-230/IP
Sounder/alarm
indicator
? ? ? ? ? 100 2 c IP65
Supported only
by AutroSafe
version 4.3 or
later
116-BU-47
Conventional
alarm indicator
? ? – – IP30
116-7770-009.0002
Roshni LP, shallow
base
? ? ? ? ?
10-
112
– IP54
*: Candela (c), Joule (j)
Alarm units (cont.)
Image Part number Descrtption
Loop mounted/addressable
Alarm output mounted
Electronic
Signal presets
Configurable
Watertight
Sound
Light
Sound output (dBA/1 m)
Light output (c/j)*
Ingress Protection level
Notes
116-7770-009.0004
Roshni LP, shallow
base
? ? ? ? ? 102 – IP54
116-7770-009.0005 Roshni, deep base ? ? ? ? ? 102 – IP65
116-7780-004.0001
Flashni, shallow
base
? ? ? ? ? 101 0,7 j IP54
116-7780-004.0002 Flashni, deep base ? ? ? ? ? 101 0,7 j IP65
116-7782-001.0003 Sounder ? ? 110 –
IP66
/67
48 VDC
ATEX approval
Ex II 2GD
EExd IIC T5
116-4340-006.0201 Xenon beacon ? ? – 5 j
*: Candela (c), Joule (j)
40 Autronica Fire and Security AS, Petrochemical, Oil & Gas 41
PRODUCTS 2016
Loop units
Alarm units
Alarm units (cont.)
Image Part number Descrtption
Loop mounted/addressable
Alarm output mounted
Electronic
Signal presets
Configurable
Watertight
Sound
Light
Sound output (dBA/1 m)
Light output (c/j)*
Ingress Protection level
Notes
116-4340-006.0924
Solex beacon,
shallow base
? ? ? – 2,5 c IP54
116-4340-006.0925
Solex beacon, deep
base
? ? ? – 2,5 c IP65
116-4340-006.0926
Solex beacon,
shallow base
? ? ? ? – 2,5 c IP54
116-4340-007.0001
Solista LX beacon,
wall mounted ,
deep base
? ? ? ? ? –
W-
2.4-
7.5
IP65 Red flash
116-4340-007.0002
Solista LX beacon,
ceiling mounted,
shallow base
? ? ? ? ? –
C-3-
7.5
IP33C Red flash
116-4340-007.0005
Symphoni LX
WP conventional
base beacon, wall
mounted
? ? ? ? ? ? –
W-
2.4-
7.5
IP66 Red flash
116-7770-009.0040 Symphoni IP66 ? 100 - IP66
For use with 116-
4340-007.0005
*: Candela (c), Joule (j)
Alarm units (cont.)
Image Part number Descrtption
Loop mounted/addressable
Alarm output mounted
Electronic
Signal presets
Configurable
Watertight
Sound
Light
Sound output (dBA/1 m)
Light output (c/j)*
Ingress Protection level
Notes
116-4340-007.0007
Solista LX wall,
shallow base
? ? ? ? ? –
C-3-
7.5
IP33C Red flash
116-4340-007.0008
Symphony G1 LX,
wall
? ? ? ? ? –
W-
2.4-
7.5
IP21C Red flash
116-4340-007.0009
Symphony G1 LX,
wall
? ? ? ? ? –
W-
2.4-
7.5
IP21C Red flash
*: Candela (c), Joule (j)
MEDC beacons, sounders, and combination units
Autronica Fire and Security AS distribute MEDC equipment. Please contact us with your request.
These products are produced according to customer specifications.
42 Autronica Fire and Security AS, Petrochemical, Oil & Gas 43
PRODUCTS 2016
Loop units
Door magnet
Door magnet
Image Part number Descrtption
116-6731-017.0002
Door magnet armature. Type AG w/adjustable socket.
For use with part no: 116-6731-017.0005
116-6731-017.0005
Door holding magnet. GPT, holdpower 650 N, 1 W, 40 mA.
Manual release push button. DNV approved.
For use with part no: 116-6731-017.0002
Accessories for loop units
Image Part number Descrtption
Suitable for EX
installations
116-BWA-100 Base for interactive detector heads, mandatory ?
116-BWB-110
Base adapter for analogue addressable detectors mounted on interactive
loops
116-BWP-100/20 Drip proof conduit box with M20 glands ?
116-BWP-100/25 Drip proof conduit box with holes for M25 glands ?
116-BWP-143A Ventilation duct adapter for smoke detectors, for interactive systems ?
Accessories for loop units (cont.)
Image Part number Descrtption
Suitable for EX
installations
116-BWP-143/SS
Ventilation duct adapter for smoke detectors, for interactive systems.
Stainless steel version for use in harsh environmental conditions, offshore
and onshore.
?
116-BJ-358/100 Pipe kit, L=100 mm ?
116-BJ-358/150 Pipe kit, L=150 mm ?
116-BJ-358/300 Pipe kit, L=300 mm ?
116-BJ-358/550 Pipe kit, L=550 mm ?
116-BJ-358/800 Pipe kit, L=800 mm ?
116-BJ-358/1000 Pipe kit, L=1000 mm ?
116-BWP-145 Heated detector base
116-8142-983.5115 Transformer 230/48 V for up to 10 BWP-45/BWP-145
116-WBW-100 Bypass unit for BWA-100 ?
116-WBW-101 Mounting plate for false ceilings ?
116-BZ-500 Galvanic barrier for Exia approved detectors, for field mounting
116-BZ-500/01 Galvanic barrier for Exia approved detectors, for cabinet mounting
116-4860-011.0100 Polycarbonate cover for manual call point BF-300V2
116-4890-021.0001 Lift flap in polycarbonate for manual call point 116-BF-502, all versions ?
116-4890-021.0010 Lift flap in stainless steel for manual call point 116-BF-502, all versions ?
116-4890-022.0001 Lift flap in polycarbonate for manual call point 116-BF-501, all versions ?
116-4890-022.0010 Lift flap in stainless steel for manual call point 116-BF-501, all versions ?
116-6571-011.1920
Cable gland M20-1.5 for Ingress Protection level IP67 for I/O units.
NB! Order with 116-6531-006.1920
116-6531-006.1920 Backnut for cable gland IP67. NB! Order with 116-6571-011.1920
116-7770-009.0008 Power base 230 V for Roshni alarm unit
44 Autronica Fire and Security AS, Petrochemical, Oil & Gas 45
PRODUCTS 2016
Loop units
Service tools for detection loops
Accessories for loop units (cont.)
Part number Descrtption
Suitable for EX
installations
116-4890-022.0010 Lift flap in stainless steel for manual call point 116-BF-501, all versions ?
116-6571-011.1920
Cable gland M20-1.5 for Ingress Protection level IP67 for I/O units.
NB! Order with 116-6531-006.1920
116-6531-006.1920 Backnut for cable gland IP67. NB! Order with 116-6571-011.1920
116-7770-009.0008 Power base 230 V for Roshni alarm unit
Service tools for detection loops
Part number Descrtption
Suitable for EX
installations
116-WAS-2000 AS2000, loop diagnostic tool
116-WBJ-5/01 Test gas dispenser for smoke detectors, excluding pole ?
116-WBJ-5/02 Telescopic pole, 1,26 m to 4,5 m, 1,8 kg ?
116-WBJ-5/03 Expansion pole, 1,13 m. 0,5 kg ?
116-WBJ-5/04 Test gas for smoke detectors ?
116-WBJ-6/01 Heat detector test kit, battery operated, 2 x batteries and charger included (for WBJ-5/02)
116-WBJ-10 Testifire smoke/heat detector test kit (head unit 2 x battery baton and fast charger)
116-WBJ-10/01 Testifire smoke/heat head unit
116-WBJ-10/02 Smoke capsule for WBJ-10 (6 pack)
116-WBJ-10/03 Solo 760 battery baton
116-WBJ-10/04 Solo 725 universal fast battery charger
116-WBJ-140 Installation/extraction tool for AutroSafe detectors ?
46 Autronica Fire and Security AS, Petrochemical, Oil & Gas 47
PRODUCTS 2016
Flame detection
Flame detectors
Protecting life, environment and
property, by any means necessary
Flame detectors
All flame detectors have 4 x M25 cable entries, unless otherwise specified. Swivel mount, glands and blind plugs are not included.
All detectors have an ambient temperature range of -55°C to + 60°C for T6 and -55°C to + 75°C for T5, unless otherwise specified.
Ingress Protection level all detectors and cameras: IP66
Image Part number Descrtption
Stainless steel housing
Aluminium housing
Addressable (built-in BNB-300)
Combination unit with camera av.
For PowerLoop
Cert. -55 °C to +125 °C for T4
With HART protocol
SIL 2 approved
Notes
116-5861-011.4310 AutroFlame X33AF multisp. IR ? ?
SIL 2 available spring
2016
116-5861-011.4320 AutroFlame X33AF multisp. IR ? ?
116-5861-011.4341 AutroFlame X33AF multisp. IR ? ? ?
116-5861-011.4360 AutroFlame X33AF multisp. IR ? ?
116-5861-011.4361 AutroFlame X33AF multisp. IR ? ?
116-5861-011.4373 AutroFlame X33AF multisp. IR ? ?
116-5861-011.4384 AutroFlame X33AF multisp. IR ? ? ? ?
116-5861-011.4385 AutroFlame X33AF multisp. IR ? ? ? ?
116-5861-011.4391 AutroFlame X33AF multisp. IR ? ? ?
116-5861-011.4392 AutroFlame X33AF multisp. IR ? ?
UL Brazil approved
3/4” NPT
116-5861-011.4393 AutroFlame X33AF multisp. IR ? ? ?
116-008279-101 AutroFlame X33AF multisp. IR ? ? ? 3/4” NPT
116-5861-011.4410 AutroFlame X33AF PL multisp. IR ? ?
116-5861-011.4411 AutroFlame X33AF PL multisp. IR ? ? 3/4” NPT
116-5861-011.4420 AutroFlame X33AF PL multisp. IR ? ?
116-5861-011.4440 AutroFlame X33AF PL multisp. IR ? ? ?
116-009009-002 AutroFlame X32AF multisp. IR ?
Hydrogen flame
detection
116-009011-002 AutroFlame X32AF multisp. IR ?
Hydrogen flame
detection
116-5861-011.3980 AutroFlame X98 single IR ? ?
116-5861-011.3981 AutroFlame X98 single IR ? ?
116-009585-001 xWatch surveillance camera ?
For use with any
flame detector above.
M20
PAL video output. For
use in EX areas FM/
CSA approved
768 x 484 px
90° optical lens*
116-009587-001 xWatch surveillance camera ?
*Other lenses available
Autronica’s flame detectors are solutions for applications in which risk to
personnel is high and where fire might result in a large loss of equipment.
Beyond critical life-safety concerns, our products have proven to minimize
total cost of ownership while minimizing false alarms.
Our industrial and commercial applications include oil and gas pipelines,
turbine enclosures, offshore platforms, and Floating Production Storage
and Offloading (FPSO) vessels.
Bottom line – no other company offers more flame-detection technologies
with wider area coverage, higher false-alarm immunity, reduced response
times, and the appropriate global approvals. And to improve ease of use, all
X-Series flame detectors have HART-protocol options.
Flame detection
Keeping a close watch
48 Autronica Fire and Security AS, Petrochemical, Oil & Gas 49
PRODUCTS 2016
Flame detection
Test equipment
Cable glands/Blind plugs
Part number Descrtption
116-6332-032.1925 Blind plug M25, polyamid, Eexe, Ingress Protection level: IP67
116-6530-030.0020 SPMH/NP/M20 blind plug nickle plated brass
116-6530-030.0025 SPMH/NP/M25 blind plug nickle plated brass
116-6571-016.2520 Cable gland adapter M20/M25
116-6571-018.2025 EEXDE adapter M25-20 nickle plated brass
116-6571-070.2025 Cable gland A2LBFM25NP, Brass - nickel plated, Exd/Exe, Ingress Protection level: IP66/68
116-6571-071.2500 Cable gland M25, polyamid, Eexe, Ingress Protection level: IP67
116-6571-080.0001 501/453/UNIV/B M25 nickle plated brass
116-6571-080.0002 501/421/B M25 EEXE nickle plated brass
116-6571-080.0004 501/453/UNIV/OS-M20 nickle plated brass
116-6571-080.0005 501/453/UNIV/O-M20 nickle plated brass
116-6571-080.0006 501/453/UNIV/A-M20 nickle plated brass
116-6571-080.0007 501/421/Os M20 EEXE nickle plated brass
116-6571-080.0008 501/421/O M20 EEXE nickle plated brass
116-6571-080.0009 501/421/A M20 EEXE nickle plated brass
Accessories
Part number Descrtption
116-001680-001 K1003A1006 Window cleaner for flame detectors (6 pcs.)
116-004404-002 Q9001H8001 swivel for xWatch camera SS
116-002099-003 Q9001B1175 swivel for xWatch camera alu.
116-5861-011.9050 Q9033B Swivel mount for AutroFlame detectors, stainless steel
116-5861-011.9051 Q9033A Swivel mount for AutroFlame detectors, aluminium
116-007338-010 Q2033A10R 10 degree field-of-view limiter
116-007338-020 Q2033A20R 20 degree field-of-view limiter
116-007338-030 Q2033A30R 30 degree field-of-view limiter/Weather shield (maintains standard field-of-view)
116-007240-001 Q1116A air shield assembly
116-009199-001 Q1198A dual air shield/flange mount assembly
116-102740-002 Calibration magnet for X series flame detectors
Test equipment
Part number Descrtption
116-006439-004 W8067S Long range test lamp IR/UVIR, (non-EX)
116-004000-006 W867C Portable test lamp 220 V, UV, UV/IR & Single IR
116-007255-001 Q1201C Laser holder for AutroFlame X33AF, UV/IR and UV flame detectors
116-006097-001 Laser aimer (non-EX) for AutroFlame detectors incl. battery
116-009997-001 Charger and battery, for test lamp 116-004000-006
116-007819-001
W6300B Inspector connector for connection to PC utilizing an integral RS485 to RS232 converter
for communication
116-009207-001 Inspector monitor software. To be used together with inspector connector
116-009208-001 O/I replacement kit for AutroFlame X33AF with black reflector plate*
116-010831-001 O/I replacement kit for AutroFlame X33AF with stainless steel reflector plate*
116-009208-002 O/I replacement kit for AutroFlame X22, X52 and X98
116-102740-002 Test magnet for AutroFlame X33AF
116-007739-001 Test magnet and extension pole
*Please note: AutroFlame X33AF models are supplied with either a black or a stainless steel reflector plate. These plates are not interchangeable. Order
the replacement that matches the reflector plate on your AutroFlame X33AF detector.
50 Autronica Fire and Security AS, Petrochemical, Oil & Gas 51
PRODUCTS 2016
Gas detection
Infrared hydrocarbon gas detectors
When it comes to detecting toxic gas would you rather be alerted in 30
seconds... or 5 seconds?
In the demanding environments of the petrochemical oil and gas industry,
fire and gas detection has to deliver optimal results at all times. Autronica
offers traditional detectors with 4-20 mA and/or relay output, but we have
also taken the IR point gas detection a step further. By introducing the
two wire intelligent communication on our IFG PowerLoop we allow for
centralized control of all diagnostic data. Analogue readings and detector
self testing features are available from our AutroPoint IR gas detectors.
The line-of-sight IR gas sensing technology surpasses other alternatives,
both with respect to the life cycle cost as well as operational tangibles of
a more technical nature. Our AutroPath HC800 open path infrared beam
system delivers reliable, combustible gas monitoring for all types of
applications.
The AutroSonic Acoustic Gas Leak Detector hears gas leaks that others
don’t – the instant they occur. It is the first non-contact gas leak detector of
its kind that recognizes unique sound “fingerprints,” analyzing 24 discrete
ultrasonic bands, while ignoring nuisance ultrasonic sources. A highfidelity
microphone continuously monitors for the distinct ultrasound
emitted by pressurized gas leaks across the widest spectrum of frequencies.
With our AutroTox toxic gas detector family, you get a gas detector that
continuously monitors the atmosphere for potentially hazardous gas leaks
and oxygen depletion. An array of sensor models detect a variety of gases
in various concentration ranges.
Autronica delivers the performance, quality, and reliability you can depend
on to keep you safe and satisfied.
Gas detection
When every second counts
Infrared hydrocarbon gas detectors
All units have 4-20 mA with HART protocol and are delivered in stainless steel housing.
Image Part number Descrtption
SIL 2 approved
HART connector
Hydrophobic filter*
Relay output
Cable entries EX approval Notes
116-010195-232
AutroPoint HC200
? 2 x M25 Ex d e
116-5861-011.5100 ? ? 2 x M25 Ex d e
116-010195-233 ? ? 2 x M25 Ex d
116-007168-233 ? ? ? 2 x M25 Ex d
116-010195-234 ? ? 2 x M25 Ex d e
116-007168-234 ? ? ? 2 x M25 Ex d e
116-010195-235 ? ? ? 2 x M25 Ex d
116-007168-235 ? ? ? ? 2 x M25 Ex d
116-010195-236 ? 2 x 3/4” NPT Ex d Inmetro
116-010195-237 ? ? 2 x 3/4” NPT Ex d Inmetro
116-007168-252 ? ? 2 x 3/4” NPT Ex d e
116-5861-011.5300
AutroPoint
HC300PL
? 2 x M25
Ex d e
Addressable,
PowerLoop version
116-5861-011.5301 ? ? 2 x M25
116-010195-030 ? 2 × M25
116-010195-036 2 × M25
116-010195-031 ? 2 × ?’’ NPT
116-010195-037 2 × ?’’ NPT
116-5861-011.5310 ? 2 × ?’’ NPT
116-013800-503
AutroPath HC800
?
M25 Ex d e
5-60 m range
Atex/IECEX
116-013800-553 ?
30-120 m range
Atex/IECEX
116-013801-503 ?
Transmitter spare
Atex/IECEX
116-013802-503 ?
Reciever spare 5-60 m
Atex/IECEX
116-013802-553 ?
Reciever spare 30-120 m
Atex/IECEX
116-013803-503 ?
Transmitter front module
ATEX/IECEX
116-013804-503 ?
Receiver front module
5-60 m
ATEX/IECEX
116-013804-553 ?
Receiver front module
30-120 m
ATEX/IECEX
*: Recommended for areas with high levels of airborne particulates or humidity.
Other detectors available on request.
52 Autronica Fire and Security AS, Petrochemical, Oil & Gas 53
PRODUCTS 2016
Gas detection
Toxic gas detectors
Infrared hydrocarbon gas detectors (cont.)
All units have 4-20 mA with HART protocol and are delivered in stainless steel housing.
Image Part number Descrtption
SIL 2 approved
HART connector
With hydrophobic filter*
With relay output
Cable entries EX approval Notes
116-GD10-P00-17DG-
0XH-00
GD-10P ? ? 2xM20 Ex d e 1 sec. response
116-Z-02104N4011
Searchline Excel IR
gas detector
116-Z-02104NXSSA
With SNX universal
transmitter
*Recommended for areas with high levels of airborne particulates or humidity.
Other detectors available on request.
Acoustic gas detectors
All units have 4-20 ma with HART protocol and are delivered in stainless steel housing.
Image Part number Descrtption
SIL 2 approved
HART connector
With hydrophobic filter*
With relay output
Cable entries EX approval Notes
116-012152-001
AutroSonic acoustic
gas detector kit
? ?
3/4” NPT
Ex d
FM/CSA/ATEX/IECEX
approved.
Kit includes individually
packaged sensor and
116-012153-001 M25 transmitter.
Toxic gas detectors
Autronica provides toxic gas detectors for a wide range of gases. These detectors must be combined with a toxic gas sensor module, listed below. All
display units are Ex d approved, having 4-20 mA output with HART and RS-485 in addition to relay outputs.
Image Part number Descrtption
Electrochemical
Stainless steel housing
Aluminium housing
Notes
116-5861-011.6601
AutroTox ATD w/AutroVu AV10 display unit
? ?
SIL 2 approved
116-5861-011.6603 ? ?
Toxic gas sensor modules
Image Part number Descrtption Range
Used with Omicron
point gas detection system
OGS 2.1 (page 67)
Used with Omicron
gas sampling system
OGS 3.1 (page 71)
SIL 2 capable
116-009471-001 GTS H2S 20P 0 – 20 ppm ?
116-009471-002 GTS H2S 50P 0 – 50 ppm ?
116-009471-003 GTS H2S 100P 0 – 100 ppm ?
116-009471-004 GTS Cl2 10P 0 – 10 ppm
116-009471-006 GTS NH3 500P 0 – 500 ppm
116-009471-008 GTS H2 1000P 0 – 1000 ppm ?
116-009471-009 GTS O2 25V 0 – 25 % by volume ? ? ?
116-009471-010 GTS CO 100P 0 – 100 ppm ?
116-009471-011 GTS CO 500P 0 – 500 ppm
116-009471-503 GTS H2S 100PTD, DNV approved 0 – 100 ppm ?
116-009471-509 GTS O2 25VTD, DNV approved 0 – 25 % by volume ?
116-009471-510 GTS CO 100PWD, DNV approved 0 – 100 ppm
116-009471-511 GTS CO 500PWD, DNV approved 0 – 500 ppm
116-009471-532 GTS H2S 50P, DNV approved 0 – 50 ppm ? ?
INMETRO approved versions available
54 Autronica Fire and Security AS, Petrochemical, Oil & Gas 55
PRODUCTS 2016 粉尘浓度检测探头 BCJ-Y-C,L=950 4 套 插入深度950mm
Gas detection abb氧化锆加热组件 AZ200704
Accessories
Display units
All display units are Ex d approved, having 4-20 mA output with HART and RS-485 in addition to relay outputs.
Image Part number Descrtption
Electrochemical
Catalytic combustible
Stainless steel housing
Aluminium housing
SIL 2 approval
Cable entries
Notes
116-011780-001 AutroVu AV10 ? ? ? 5xM25
116-011780-002 AutroVu AV10 ? ? ? 5xM25
116-011780-006 AutroVu AV10 ? ? ? 3/4 NPT
116-011780-081 AutroVu AV10 ? ? ? 3/4 NPT INMETRO (Brazil)
116-011780-082 AutroVu AV10 ? ? ? 3/4 NPT INMETRO (Brazil)
116-011780-003 AutroVu AV10 CGS ? ? 5xM25
116-011780-004 AutroVu AV10 CGS ? ? 5xM25
Toxic gas transmitters and termination boxes
Image Part number Descrtption
Electrochemical
Stainless steel housing
Aluminium housing
Eex d certified
Notes
116-009480-004 GTX Transmitter ? ? ?
Used with Omicron point gas detection
system OGS 2.1 (page <?>) and OGS 3.1
(page 71)
116-226365-601 STB Termination Box ? ? ?
For GT3000, M25, SS, 5 ports
116-226365-603 STB Termination Box ? ? ?
Accessories
Part number Descrtption
116-007525-003 Direct duct mount kit for point gas detectors AutroPoint HC200 and HC300PL
116-009700-001 Magnetic tool for AutroSonic acoustic detector and AutroVu display
116-012513-001 Q912 Duct mount M25 with 1 ft. inlet
116-012513-003 Q912 Duct mount M25 with 3 ft. inlet
116-012513-006 Q912 Duct mount M25 with 3 ft. inlet
116-012513-010 Q912 Duct mount M25 with 10 ft. inlet
116-012513-013 Q912 Duct mount M25 with 13 ft. inlet
116-012673-001 System test film for AutroPath HC800, set of 5 films
116-012287-002 Alignment telescope for AutroPath HC800
116-226365-111 Toxic sensor termination box and separation kit. JBOX, SEP, AL, M20 CENELEC toxic
116-226365-127 Toxic sensor termination box and separation kit. JBOX, SEP, AL, M25 CENELEC Infinity
116-US-843 Rain and sun shield for point gas detectors AutroPoint HC200 and HC300PL
116-Z-475HP1EKL9GMT
Emerson 475 HART communicator. Instrument for calibration of AutroPoint HC200 and
AutroPath HC600 gas detectors. Certified intrinsically safe by CENELEC/ATEX, FM, CSA, FISCO and IECEx
116-Z-GD10-ADAPT1 Duct adapter for point gas detector GD-10P
116-Z-499815712 Sunshade, GD10/PGD10PE
116-Z-ES-244 Gas detector test point
For cable glands and blind plugs, see flame detector section, page 48.
56 Autronica Fire and Security AS, Petrochemical, Oil & Gas 57
PRODUCTS 2016
Gas detection
Calibration kits
Calibration kits
Part number Gas type Concentration Notes
116-006468-001 Methane CH4 50 % LEL AutroPoint HC200/-300
116-007098-005 Hydrogen Sulphide H2S 50 ppm 12 x ampoules, NTMOS detectors
116-010274-001 Hydrogen Sulphide H2S 10 ppm GT3000 series
116-010274-002 Hydrogen Sulphide H2S 25 ppm GT3000 series
116-010274-004 Chlorine Cl2 5 ppm GT3000 series
116-010274-005 Ammonia NH3 50 ppm GT3000 series
116-010274-006 Ammonia NH3 250 ppm GT3000 series
116-010274-008 Hydrogen H2 500 ppm GT3000 series
116-010274-009 Oxygen O2 20,90 % GT3000 series
116-010274-010 Carbon Monoxide CO 50 ppm GT3000 series
116-010274-011 Carbon Monoxide CO 250 ppm GT3000 series
116-010274-013 Sulfur Dioxide SO2 10 ppm GT3000 series
116-010274-014 Sulfur Dioxide SO2 50 ppm GT3000 series
116-225130-005 Hydrogen H2 50 % LEL AutroPoint H2
116-225130-009 Without gas – AutroPoint H2
Accessories for calibration kits
Part number Descrtption
116-004976-001 Calibration cup for catalytic detectors, stainless steel
116-005964-001 Calibration cup for point gas detectors AutroPoint H2S, O2 and TX50
116-006672-002 Windshield calibration bag for AutroPoint HC200/-300
116-225741-001 Extra ampoules for 116-007098-005 NTMOS Calibration Kit H2S Ampoule, 50 ppm
116-227117-001 GT3000 replacement cylinder H2S 50 ppm
116-227117-006 GT3000 replacement cylinder O2 20,90%
116-227117-012 GT3000 replacement cylinder H2S 25 ppm
116-227117-018 GT3000 replacement cylinder H2 500 ppm
116-Z-00670 Step regulator with 0,5 L constant flow
116-Z-00671 Step regulator with 1 L constant flow
116-Z-00678 Carrying case for 2 bottles
116-Z-1200674 2.5 LPM constant flow regulator
116-Z-1711020 Test gas, 65 % LEL methane in N2. 110 L
116-Z-1501020 Test gas, 50 ppm H2S. 110 L
116-Z-1404010 Test gas, 50 % LEL H2. 110 L
116-Z-499810874.8 Sample Flow Housing for point gas detector GD-10P
116-Z-03150 Viton hose pr. meter
116-Z-1200673 Reg. valve 0.3-3.0 L/min
Other concentrations and test gases available on request.
58 Autronica Fire and Security AS, Petrochemical, Oil & Gas 59
PRODUCTS 2016
Other detectors
Alarmline linear heat detectors
Alarmline linear heat detectors
Image Part number Descrtption
116-AD68N-0001 Digital cable, 68 °C nylon
116-AD88N-0001 Digital cable, 88 °C nylon
116-AD105N-0001 Digital cable, 105 °C nylon
116-AD185SS-0001 Digital cable, 185°C stainless steel and nylon
116-AAN-0001 Analogue LHD cable, nylon
116-AACUSP Analogue LHD control unit, self programmable
Recommended interface unit for Alarmline linear heat detectors is BN-303 (see page 28)
Accessories
Part number Descrtption
116-5843-005.9002 Alarmline L-bracket
116-5843-005.9003 Alarmline edge clip
116-5843-005.9004 Alarmline T-clip
116-5843-005.9005 Alarmline pipe clip
116-5843-006.0010 Termination kit K82023
116-5843-007.0001 EEXE Junction box tank roof
116-5843-007.0002 Automatic cable reel
116-5843-007.0003 Neoprene sleeve B6782-08
116-5843-007.0004 Cable ties B6782-121
Other detectors
– completing the fire detection system
Alarmline linear heat detection (LHD) is a cable-based system providing
economical temperature monitoring at the precise point of risk.
The system is reliable, flexible and has the ability to detect abnormal
temperature variances before fire breaks out. The comprehensive LHD
product portfolio allows a vast range of commercial and industrial fire and
overheat risks to be protected, in ambient temperatures of 68°C to 185°C.
Other options/alarm temperatures available on request.
Aspirating detectors function by sampling air via a network of pipes,
sampled air is passed through a dust filter and into a detector chamber
where the air is analyzed for traces of smoke. Typical applications include
laboratories, large open spaces, corrosive environments, archives/
historical buildings and industrial areas. Every detector is “trainable” for
the specific environment in which it is installed.
Common to all AutroSense detectors is that they are capable of detecting
the small amounts of smoke that are generated in the initial phases of a
smouldering fire, ensuring the earliest possible warning of a potential fire.
At the same time, AutroSense detectors distinguish real smoke from dust
and pollutants, reducing unwanted alarms to a minimum.
AutroSense 200, AutroSense Micra 25 and Micra 100 are stand-alone
aspirating detectors, that can also be connected to fire alarm systems.
These units feature built-in intelligence that ensures optimal detection
capability.
Beam detectors are used in large open areas instead of a quantity of point
smoke detectors. The detector protects a given area by sending signals
(infrared light beam) between a transmitter and receiver, and detect
dimmer or changes in frequency by heat or smoke. Beam detectors are
suited to applications in open spaces where costs associated with point
smoke detectors would be prohibitive.
60 Autronica Fire and Security AS, Petrochemical, Oil & Gas 61
PRODUCTS 2016
Other detectors
Accessories
Aspirating detectors
Image Part number Descrtption
Sensitivity
(obsc./m)
Max.
length
piping
Max.
coverage
(FG)
Max.
coverage
BS6266
(Hot Wire
Test)
Sampling pipe inlets
Max. sampling holes
Alarm levels
Relays
116-5861-018.2000 AutroSense 200 0,0015–25% 200 m 2000 m2 500 m2 4 100 4 5
116-5861-018.1007 AutroSense Micra 25 0,0015–25% 25 m 450 m2 450 m2 1 10 1 2
116-5861-018.1107 AutroSense Micra 100 0,0015–25% 100 m 1600 m2 500 m2 2 50 1 2
116-5861-018.1500
AutroSense Cascade
Display Module
116-5861-018.1501 AutroSense Cascade 0,0015–25 % 100 m 1 50 4 3
Recommended interface unit for AutroSense 200 is BN-305 (see page 28)
Recommended interface unit for AutroSense Micra is BN-303 (see page 28)
Recommended interface unit for AutroSense Micra is BN-304 (see page 28)
Accessories
Part number Descrtption
116-5861-018.2110 AutroSense command module w/o PSU
116-5861-018.4110 AutroSense Micra relay card w/inputs
116-5861-018.9027 AutroSense 200 dust filter
116-5861-018.9028 AutroSense Micra 25 and 100 dust filter
116-5861-018.3051 Wire burn unit
116-5861-018.9999 Cable for “hot wire” test (roll @ 100 m)
116-5861-018.2433 AutroSense air heater
116-XJA-030 Programming cable for AutroSense Micra
116-BW-75/04 Condensation bottle
116-BW-75/06 Filter
116-BWP-144 AutroSense, detector housing for sampling pipes with detector base BWA-100
116-BWP-44 AutroSense, detector housing for sampling pipes with detector base BWA-40A/1
116-E-2446/2 Label for sampling pipe “Warning”
116-5861-966.0009 Smoke pellets
116-5861-966.0010 Smoke matches
Piping ?’’ (27 mm) – halogen free
Image Part number Descrtption
– 116-5862-001.0025
Water hose in coil, 25 mm PE50 NT10.
Please specify desired length: 50 or 300 meters
116-5861-910.0027 Straight pipe L = 3 m
62 Autronica Fire and Security AS, Petrochemical, Oil & Gas 63
PRODUCTS 2016
Other detectors
Accessories
Piping ?’’ (27 mm) – halogen free (cont.)
Image Part number Descrtption
116-5861-914.1027 Joining socket
116-5861-964.0001 T-piece
116-5861-915.1027 Socket union
116-5861-962.0001 Normal bend 45°
116-5861-912.0027 Normal bend 90°
116-5861-964.0002 End cap
116-5861-965.0001 Adapter 27 mm - 25 mm, female/male
Piping ?’’ (27 mm) – halogen free (cont.)
Image Part number Descrtption
116-5861-966.0005 Adapter 27 mm - 25 mm, female/female
116-5861-964.0008 Adapter 25 mm - 27 mm, female/male
116-5861-922.0004 T piece for capillary
116-5861-964.0004 Plane test point with 10 mm adapter, 90°
116-5861-922.0007 Discreet capillary sampling point, 10 mm
116-5861-910.0078 10 mm capillary tube
116-5861-018.9021 Capillary sampling point kit flush
64 Autronica Fire and Security AS, Petrochemical, Oil & Gas 65
PRODUCTS 2016
Other detectors
Accessories
Piping ?’’ (27 mm) – halogen free (cont.)
Image Part number Descrtption
116-5861-935.0002 Solvent cement 250 ml w/brush
116-5861-922.0001 Test point, plane shape
116-5861-922.0010 Sampling hole warning label
116-5861-964.0006 Pipe clip
116-5861-966.0001 Compression adapter 27 mm / 10 mm
116-5861-966.0002 Compression adapter T 27 mm / 10 mm
116-5861-966.0003 ABS test point
Piping ?’’ (27 mm) – halogen free (cont.)
Image Part number Descrtption
116-5861-966.0004 Glass condensation trap
116-5861-966.0005 Flexible connector 30 cm
116-5861-966.0006 Flexible connector 100 cm
116-5861-966.0007 Condensation trap with valve
116-5861-966.0008 Self bilging condesation trap
66 Autronica Fire and Security AS, Petrochemical, Oil & Gas 67
PRODUCTS 2016
Other detectors
Beam detectors
Beam detectors
Image Part number Descrtption
Detection
distance
Ingress
Protection
level Notes
116-5861-023.5101
FireRay 5000-101
Auto aligning infrared optical beam smoke
detector. Transmitter/receiver in the same
housing, plus reflector.
5 – 50 m IP54
116-5861-023.5102
FireRay 5000-102
Auto aligning infrared optical beam smoke
detector. Transmitter/receiver in the same
housing, plus reflector.
50 – 100 m IP54
116-5861-023.3000
FireRay 3000-101
End to end infrared optical beam smoke detector
system. Transmitter, receiver and compact lowlevel
controller.
5 – 120 m IP54
Recommended interface units for FireRay detectors are BN-303 or BN-305 (see page 28)
Accessories
Image Part number Descrtption
116-5861-023.5002 FireRay 5000-002: For 50 m – detector head and 1 x reflector
116-5861-023.5039 FireRay 5000-03: For 100 m – detector head and 4 x reflector
116-5861-023.5003 FireRay 5000-003: System controller
116-5861-023.5005
FireRay 5000-005Universal bracket for use with FireRay 5000 detector head or reflector mounting
plate
Accessories (cont.)
Image Part number Descrtption
116-5861-023.5006 FireRay 5000-006: Surface mounting plate for 1 or 4 reflectors
116-5861-023.5007
FireRay 5000-007: Mounting plate for 4 reflectors for use with bracket FireRay 5000-005
Image shows plate mounted on bracket, with reflector
116-5861-023.5008
FireRay 5000-008: Mounting plate for 1 reflector for use with bracket FireRay 5000-005
Image shows plate mounted on bracket, with reflector
116-5861-023.5004 50-100 m kit for FireRay 5000, consisting of 3 reflectors. Included in FireRay 5000-102
116-5861-023.1018 Protection cage for FireRay 5000
116-5861-023.3001 FireRay 3000-015: Pair of detectors (transmitter and receiver) for use with FireRay 3000 system
116-5861-023.3002 FireRay 3000-201: Adjustment bracket for use with FireRay detectors
68 Autronica Fire and Security AS, Petrochemical, Oil & Gas 69
PRODUCTS 2016
Omicron systems
Point gas detection system – OGS 2.1
Every day, thousands of vessels and offshore production facilities navigate
the world’s oceans, containing valuable and often high-risk products. We
are dedicated to the crew onboard, always doing our best to ensure that
they have the safest working conditions possible.
Each application is unique in design or task, and it is our mission to provide
each one with an optimal safety system. Autronica’s Omicron product
range is designed to meet the most demanding requirements within the
offshore industry. For more than 25 years we have designed gas detection
systems to meet and exceed the individual demands of each installation.
The entire value chain, from project engineering via production to after
sales and administration, is bundled in our Special Detection Competence
Center in Norway, ensuring fast, efficient and high quality project
realization. Based on the experience of approximately 200 projects per year
and our thorough application know-how our team of dedicated and highly
specialized employees will always find the ideal solution for your needs.
Since 1989 we have developed and optimized a range of high end systems
that require minimal maintenance, are extremely robust and reliable as
well as easy to operate. Our service-friendly systems fulfill all regulatory
and class societies’ regulations and enable economically viable operations.
Omicron system can be used in various applications like e.g. FPSO, FSRU,
platforms or drilling rigs.
Omicron systems
Solutions you can trust
Premium quality
safety monitoring and
environmental surveillance
Point gas detection system – OGS 2.1
For all high risk areas that require fast and continuous gas detection
Our point gas detection system OGS 2.1 is the ideal solution for environments that require continuous
monitoring for hazardous gases.
Typical higher risk areas that require fixed point gas detection are e.g. pump rooms and engine
rooms. The system can be equipped with an infinite number of sensors and supports various
detection methods such as e.g. electrochemical, catalytical and infrared technology.
The OGS 2.1 system operates on the same platform as our gas sampling family OGS 3, making it
easy combinable and the ideal extension to the OGS sampling systems whenever both solutions
need to be pooled to one economically sound system. The platform flexibility enables us to meet the
individual customer’s needs.
The OGS 2.1 meets the requirement set out by IMO and the different classification societies.
Features
? Individual readings and alarm LEDs for each individual sensor
? Up to 4 adjustable independent alarm set points
? Detection of Oxygen, Hydrocarbons and toxic gases
? Infrared, catalytical and electrochemical sensors
? Continuous system verification
? Intuitive operation
? Remote alarm unit to display alarms on a second location e.g. ship’s bridge (optional)
? Integrated temperature alarm for cargo pump bearings (optional)
? Cargo pump emergency shutdown (option)
? RS 485/422 Modbus RTU serial line communication (option)
? Separated alarm and detector cabinet (optional)
Part number Name Descrtption
116-KIT-K2001 Gas alarm system OGS 2.1
Control cabinet with integrated alarm panel for a fixed gas detection
system with a set number of sensors. Cabinet to be operated in indoor
safe area. Standard Autronica project documentation included.
Number of sensors must be specified when ordering.
OGS 2.1 Gas Sensors & Accessories
Part number Name Descrtption
116-010195-058 AutroPoint HC200 IR Sensor 0 - 100% LEL, 2 x M25 cable entries
116-M2050 Modbus OGS 2.1
For GT3000 toxic gas sensors, see
? “Accessories” on page 55
? “Toxic gas sensor modules” on page 53
70 Autronica Fire and Security AS, Petrochemical, Oil & Gas 71
PRODUCTS 2016
Omicron systems
Gas sampling system – OGS 3.1
Gas sampling system – OGS 3.1
For total solutions in gas sampling
The OGS 3 family is our 4th generation gas sampling systems, relied
on by major operators around the world. Built to withstand the
harshest conditions, the Omicron Gas Sampling Systems are the
ideal solution for gas detection in areas where normal installation
of gas sensors is impossible.
The OGS 3.1 is our top of the range gas sampling system and
typically used in the oil and gas offshore industry. The system
contains a monitoring cabinet and a detector cabinet, that both can
be installed in EX areas. The system’s scalability enables us to design
the ideal solution for the individual operational challenges on e.g.
FPSOs, FLNG or drilling rigs. OGS 3.1 meets the requirement set out
by IMO and the different classification societies.
Intuitive and efficient
Within standard operation the OGS system runs a fully automated
sampling sequence from the various defined sampling points. The cycle time is minimized by using 2 independent vacuum pumps; one main pump
that continuously draws air from all sample points and one smaller pump taking samples from the actual point according to the sample sequence. This
ensures fresh samples and a quick response in case gas is detected. The system continuously self verifies all pneumatic components to ensure proper
operation at all times. All alarms, gas as well as potential malfunctions, are shown on the standardized Omicron operator panel in plain text, making the
operation extremely intuitive and limiting training requirements, especially for combined systems.
Scalability
The wide range of optional features in conjunction with the overall system flexibility allow Omicron Gas Sampling Systems to cover a brought range of
applications, ranging from a system with only a few sample points to a tailor made OGS 3.1 system with a centralized monitoring cabinet and several
detector cabinets, making it the ideal solution for large and demanding applications. The system utilize the common Omicron product line platform,
which makes it easily combinable with the Omicron fixed gas detection system OGS 2.1 creating an overall cost effective gas detection solution for an
entire vessel.
Features
Part number Name Descrtption
116-KIT-K3001 OGS 3.1 Alarm & control cabinet
IP66 Control cabinet with integrated alarm panel for a set number of
sample points. Cabinet to be operated in safe area. Standard Autronica
project documentation included.
Number sampling points must be specified when ordering.
116-KIT-K3010 OGS 3.1 Detector cabinet
IP66 detector cabinet incl. 1 AutroPoint HC200 0-100% LEL IR sensor,
flame arrestors and manifolds for a set number of sample points. Cabinet
to be operated in safe area. Standard Autronica project documentation
included.
Number sampling points must be specified when ordering.
Customer specific configuration and documentation and/or other sensor types on request
Standard
? Infrared hydrocarbon sensor(s) with range 0 - 100% LEL
? Low and high gas alarms
? Flame arrestor and shut off valves for each sampling tube
? Automatic and sequential purging of each sampling tube
? Two vacuum pumps for reliable detection (main and sample)
? Non-return valves to avoid liquid entering into the system
? Continuous system verification
? Adjustable purge and sample time on every sampling point
? Semi-automatic test functionality for span and zero calibration
? Manual disconnecting of sampling points that are not in use.
Optional
? Multiple gas analysis. Up to 3 different gas sensors simultaneously
? Dilute functionality for detection of non IR detectable combustible
gases (e.g. NH3)
? Repeater display units with control transfer (max. 5)
? Remote alarm units with alarm LEDs and sounder (e.g. for bridge)
? Bulkhead penetrations
? RS 485/422 Modbus RTU serial line communication
? Up to 32 freely configurable aux. relay outputs
? Dual purge supply (i.e. nitrogen and instrument air)
? Standby pump with manual switch over
? Eex, Zone 1 design
? Special design materials for extreme gases
OGS 2.1 classification
Part number Name
116-Classification Classification by class society
OGS 2.1 spare part kit
Part number Name
116-M6170 OGS 2.1 standard spare part kit
116-M6171 OGS 2.1 3 years spare part kit
72 Autronica Fire and Security AS, Petrochemical, Oil & Gas 73
PRODUCTS 2016
Omicron systems
Gas sampling system – OGS 3.1
OGS 3.1 sensors and system options
Part number Name Descrtption
116-M3252 GT3000 flow cap
116-M3035 Modbus OGS 3
116-M3050 Flamescreen OFS1/10MMOD Flamescreen for exhaust air
116-M3051 FLAMESCREEN OFS1/12mmOD Flamescreen for exhaust air
116-M3078 Shut-off valve 1X6MMOD EX HEX
116-M3079 SShut-off valve 1X6MMOD W/HEX
116-M3080 Shut-off valve 2X8MMOD
116-M3081 Shut-off valve 1X8MMOD
116-M3082 Shut-off valve 2X10MMOD
116-M3083 Shut-off valve 1X10MMOD
116-M3084 Shut-off valve 2X12MMOD
116-M3085 Shut-off valve 1X12MMOD
116-M3140 Filter regulator 12MMOD-12MMTX
116-M3141 Filter regulator 10MMOD-12MMTX
116-M3142 Filter regulator 8MMOD-12MMTX
116-M3060 Bulkhead pen 150/32/ 2X8MM OD
116-M3061 Bulkhead pen 150/32/ 1X8MM OD
116-M3062 Bulkhead pen 150/32/ 2X10MM OD
116-M3063 Bulkhead pen 150/32/ 1X10MM OD
116-M3064 Bulkhead pen 150/32/2X12MMOD
116-M3065 Bulkhead pen 150/32/1X12MMOD
116-M3066 Bulkhead pen 150/22/2X8MMOD
116-M3067 Bulkhead pen 150/22/ 1X8MM OD
116-M3068 Bulkhead pen 150/22/2X10MMOD
116-M3069 Bulkhead pen 150/22/1X10MMOD
116-M3070 Bulkhead pen 150/22/2X12MMOD
116-M3071 Bulkhead pen 150/22/1X12MMOD
116-M3122 Non-return valve 8MM OD SS
116-M3123 Non-return valve 10MM OD SS
116-M3105 Inline filter 90MICRON/8MMOD
116-M3106 Inline filter 90MICRON/10MMOD
116-M3110 Endline filter 8MM OD
116-M3111 Endline filter 10MM OD
116-75321 Water trap
For GT3000 toxic gas sensors, see
? “Accessories” on page 55
? “Toxic gas sensor modules” on page 53
OGS 3.1 spare part kits
Part number Name
116-M6180 OGS3.1 standard spare part kit
116-M6181 OGS3.1 3 years spare part kit
116-M6182 OGS3.1 5 year spare part kit
116-M6183 OGS3.1 standard spare part kit for LPG
116-M6184 OGS3.1 3 years spare part kit for LPG
116-M6185 OGS3.1 5 years spare part kit for LPG
74 Autronica Fire and Security AS, Petrochemical, Oil & Gas 75
PRODUCTS 2016
Omicron systems
Standard accessories
Standard accessories
Alarm lights and horns
Part number Name
EX approval
Alarm sound frequency
Alarm colour
Sound output
Ingress Protection
level
Voltage
116-M6015 Alarm light XB11 M20 EEx d IIB T5/T6 – red – IP66/67 24 V DC
116-M6016 Alarm light XB11 M20 EEx d IIB T5/T6 – orange – IP66/67 24 V DC
116-M6017 Alarm light XB11 M20 EEx d IIC T6 – blue – IP66/67 24 V DC
116-46062 Alarm light EX XB9 EEx d IIC T6 – red – IP66/67 24 V DC
116-46069 Alarm light EX XB9 EEx d IIC T6 – red – IP66/67 220 V AC
116-46072 Alarm light EX XB9 EEx d IIC T6 – red – IP66/67 230 V AC
116-46073 Alarm light EX XB9 EEx d IIC T6 – orange – IP66/67 24 V DC
116-46077 Alarm light EX XB9 – – orange – IP66/67 220 V AC
116-M6030 Alarm horn KT75 M20 – Air driven 400 Hz – 136 dB(A) IP65 24 V DC
116-M6031 Alarm horn KT75 M20 – Air driven 800 Hz – 136 dB(A) IP65 24 V DC
116-M6032 Alarm horn EX DB3 M20 Eex d IIC T4
Electrical
400 - 3100 Hz
– 113 dB(A) IP67 24 V DC
116-M6033 Alarm horn EX DB3 M20 Eex d IIC T4
Electrical
400 - 3100 Hz
– 113 dB(A) IP67 230 V AC
116-M6034 Alarm horn A121 WR M20 – Electrical 1000 Hz – 126 dB(A) IP66 24 V DC
116-M6035 Alarm horn A105 WR M20 – Electrical 1000 Hz – 112 dB(A) IP66 24 V DC
116-M6036 Alarm horn A105 WR M20 – Electrical 1000 Hz – 112 dB(A) IP66 230 V AC
116-M6037 Alarm horn MA121 WR M20 – Electrical 1000 Hz – 126 dB(A) IP66/67 24 V DC
Test gas
Part number Name Descrtption
116-93019 Hose 6mm PA
116-93626 Quickc male 6mm open/open brass
116-94008 Reduction valve AGA Pressure reducer for test gas w/flowmeter (0-800 ml/min )
116-81029 Methane 50% LEL air 1l/12bar
116-81028 Propane 50% LEL air 1l/12bar
116-96630 N-Butane 50% LEL air 1l/12bar
116-81031 H2S 25 ppm N2 1l/12bar
116-96635 Nitrogen 1l/12bar
116-81024 Test gas. N-Butane 50% L.E.L. in air 10L
116-94009 Flow regulator for AGA 5L 10/l fixicontrol cylinder
OGS shale shaker
Gas detection in harsh areas
The OGS Shale Shaker is the newest member of the OGS product family and specially designed to enable reliable gas detection in the harshest oil and gas
environments such as shale shaker ventilation channels or similar areas where traditional gas detectors are quickly contaminated by dirt.
The OGS Shale Shaker is a direct gas sampling system consisting of a zone 1 approved detector cabinet including operation panel and a high end sample
probe. The sample probe provides each sampling point with two sampling tubes. While one tube draws the gas to the sensor, the other one is being
cleaned and vice versa. This provides continuous and reliable detection in the monitored area.
Features
? Specially designed for gas detection in shale shaker ventilation
? Dual sampling channels enabling reliable detection
? Automatic self cleaning routine
? IR sensor technology
? Continuous system verification
? Limited installation costs
? High end sample probe competible with standard flange
? Sample gas flow alarm
? Sample gas inlet temperature up to 70°C
? Up to 50m sampling tube
? Zone 1 approved
Part number Name Descrtption
116-KIT-K3200 OGS shale shaker standard
Gas sampling system for Shale Shaker applications containing 1
AutroPoint HC 200 IR sensor and standard gas sampling probe.
For use in zone 1, EX d IIB T4.
Standard Autronica project dokumentation included.
76
HEAD OFFICE STAVANGER, NORWAY
Autronica Fire and Security AS
Div. Oil & Gas
Lagerveien 24
NO-4033 Stavanger
Norway
Phone: +47 90 90 55 00
EUROPE & RUSSIA
Autronica Fire and Security AS
Div. Oil & Gas Europe
Stalsbergv. 9
NO-3128 N?tter?y
Norway
Phone: +47 90 90 55 00
WORLDWIDE SERVICE ASSISTANCE
Phone: +47 915 09753
E-mail:service.oilgas@autronicafire.no
UNITED KINGDOM
Autroncia Fire and Security AS
Div. Oil & Gas UK
c/o Chubb Fire & Security
UTC Building & Industrial Systems
Littleton Road
Ashford
Middlesex
TW15 1TZ
England
Phone: +44 (0) 1753 825 800
Mobile: +44 (0) 7796 26 26 92
THE AMERICAS & WEST AFRICA
Autronica Fire and Security AS,
Div. Oil & Gas Americas
10607 Haddington Drive, Suite 100
Houston, Texas 77043
USA
Phone: +1 713-290-8624
E-mail: afs.houston@autronicafire.no
Original Spare Parts:
Houston.orders@autronicafire.no
AUSTRALIA
Autronica Fire and Security AS
Division Oil & Gas Australia
Level 1, 271-273 Wellingston Road, Mulgrave
VIC 3170, Australia
Phone: +61 3 9518 5588
Mobile:+ 61 420 538 500
SPARE PARTS
Phone: +47 90 90 55 00
E-mail: oil.gas@autronicafire.no
MIDDLE EAST/SAUDI ARABIA
UTC Fire Safety Middle East
Office 202, Palladium Bldg
(Next to KIA car showroom)
Sheik Zayed Road
PO Box 30791
Al Barsha 1, Dubai
The United Arab Emirates
Phone: +971 0 491 99000
SOUTH KOREA
Autronica Fire and Security AS
#B 5F, Saesam B/D
Sesil-ro, Haeundae-gu
Busan
Rep. Of Korea 612-824
Phone: +82 70 71229170
24 HOUR SUPPORT - END USERS ONLY
Phone: +47 48 25 80 00
Contact information
For general sales conditions, go to www.autronicafire.com.
Our mission is clear,
to make the world a safer place to live in. We know how important this task is, and this drives us to constantly develop
smarter solutions.
Our pride and driving force are anchored in saving as many lives as possible, in protecting the environment and in securing property
around us. In many cases, the consequences of a fire are enormous, and we have undertaken to understand how they occur, develop
and can be fought. Our solutions must discover potential hazards in our surroundings as early as possible, without causing false alarms
and uncertainty. This is a delicate balance, and our technology must be equally optimised in large cruise ships, in nuclear power
Features
? Membrane made of 96 % alumina ceramics.
? No oil filling in element
? Rugged construction
? Body made of AISI 316 L
? DIN 175301-801 connector
? Accuracy 0.5 %
Descrtption
Application and general descrtption
The GT300 Pressure Transmitter is a general-purpose transmitter for use in engine rooms and other similar applications. The transmitter is available as gauge and sealed gauge. With pressure ranges up to 100 bar, and a 2-wire connection, 4 to 20 mA ouput signal.
Mechanical design
The transmitter consists of a sensing element together with an electronic unit encapsulated in the sensor body. Pressure connection is made via ISO228-G1/2A or ISO228-G1/4A at the lower end, and electrical connection is made via a DIN connector at the upper end of the transmitter. The body is made of acid resistant steel. See Fig. 2.
Pressure sensing capsule
The pressure transmitter is built around a dry, robust sensor element, made of ceramic, with internal strain gauge Wheatstone-bridge as a converting element between pressure and electrical signal. The signal given by this strain gauge is then digitized and stored together with known applied pressure and temperature. All this together forms a unique tabular for each sensor, which is kept in sensor memory for the sensor’s lifetime. This digital compensation gives a possibility for linearization and temperature
compensation of each transmitter uniquely, based on each element’s character. This enables a much higher accuracy and temperature stability than with former analogue sensors.
As the 96 % alumina membrane is resistant to most chemicals, the process medium is in direct contact with the measuring membrane, thus there is no need for costly de-coupling in the form of a filling liquid and second membrane. A filling liquid and a second membrane can be a source of errors. This is why dry capsule sensors have superior specifications compared to wet capsule.
Electrical descrtption
The pressure transmitter is connected to a 24 V power supply, 4 to 20 mA 2-wire connection.
GT300
Pressure Transmitter
P-GT300/CE Rev. D 2013-05-14
2
Installation
As this is a general-purpose transmitter, normal installation rules must be followed. The pressure transmitter is designed to be mounted vertically. The transmitter can be mounted directly to a stud welded to the measuring point, or it can be mounted on a wall with a control valve and connected to the measuring point by a tube. Standard pressure connection is ISO228-G1/2A or ISO228-G1/4A threads, and electrical connection is made via a cable gland on the connector.
Kongsberg Maritime can deliver detailed installation instructions and necessary installation material for various installations.
Power supply: 24 VDC (12 to 32 VDC
depending on load resistance)
Output signal: 4 to 20 mA
Load resistance: 0 to 1020 ohm depending upon power supply
Transmitter output
current: 3.8 mA ≤ Iout ≤ 21.6 mA
Output current with
Transmitter fault: Iout ≤ 3.6 mA
Accuracy*): 0.5 % of FRO**
Temperature drift: 0.05 % of FRO /°C (0 to +60 °C)
Compensated
temperature range: 0 to +60 °C
Long term drift: ≤ 0.3 % /year as % of nom. range
Performance degradation
during immunity test: ≤ 0.5 % of FRO
Operating ambient
temperature: -25°C to +85 °C
Storage temperature: -45°C to +100 °C
Weight: 0.3 kg
Protection grade: IP56
Power supply
Power supply to the transmitter is 24 VDC nominal, and can vary from 12 to 32 V. The allowable load resistance is determined by the minimum power supply, see Fig. 1.
Electrical connection
A CU-screened cable, with intact screen, must always be used from the transmitter to the monitoring system where the Cu-screen must be grounded at the monitoring side. Minimum cross cable is 2 x 0.5 mm2. Terminate + (plus) to terminal 1 and – (minus) to terminal 2, see Fig. 3.
Materials
Pressure connection: AISI 316
Membrane: 96% alumina ceramics
Gasket: Viton
*) Accuracy included non-linearity, hysteresis and reliability at 22?C.
**) FRO = Full Range Output
Technical specifications
Kongsberg Maritime can deliver detailed installation instructions and necessary installation material for various installations.
3
90
240
390
540
690
840
990
1140
1290
5
10
15
20
25
30
Resistance [ohm]
Power supply [VDC]
Operatin
Fig. 3: GT300 Pressure Transmitter, electrical connections
Fig. 2: GT300 Pressure Transmitter
Fig. 1: Load vs. power supply
4
Ordering key
PRESSURE CONNECTION:
V = G1/2A, AISI 316L, viton sealing
B = G1/4A, AISI 316L, viton sealing
OUTPUT SIGNAL:
4 to 20 mA, 2-wire connection 0
APPLICATION:
General / Engine room 0
ACCURACY:
0.5 %, temp. comp. 0 to 60 °C C
CABLE GLAND:
1 = M16 ? 3.5 to 8 mm
2 = M16* ? 6 to 10 mm
3 = M20 ?7 to 13 mm
ZERO POINT:
4 mA at atmospheric pressure G
4 mA at –1 bar gauge K
RANGE AND OVERLOAD PRESSURE (BAR):
Range Overload
0.6 2
1 4
1.6 4
2.5 10
4 10
6 10
10 20
16 40
25 100
40 100
60 200
100 200
Options are available. Please contact Kongsberg Maritime AS
GT3 0 0 C
Org.no.: NO 979 975 503 (MVA/VAT)
116-P-OILANDGAS/SGB, 2015-12-14 | Errors and omissions excepted. Changes may occur without warning
NEW ACTION 4380-2000 ACTION PAK ISOLATING SIGNAL CONDITIONER 120V D522149
NOVELLUS 17-00094-01
nov SSW-30 Spinning Wrench
GE 1. GE IS200AVGCG1A, 3个
2. GE DS200SHCAG1C, 3个
FLOW VACON 5MIN 22KW电机(VACON0100-3L-0046-FLOW+SCB4+DLCN)VACON0100-3L-0046-5-FLOW+SCB4+DLCN
8NCLPT-2E? EATON
carmanah M650H RED
Ingersoll Rand: CAM (Superseded item # CV-12) 30451488
495-4535-ND FILTER 2-LINE 250V 10A PANEL
PRAZISINSDREHWIDERSTAND FSG PW 70/A/IP 40 13455023 1708Z03-096.013/01
品牌 : Epcos 型号 : B84113CB110
IRDH275BM-727
NOVELLUS 27-050014-01
SMZ6112A63GT30G6 AMPHENOL - CONNECTOR
SMZ6112A63GT30G6 AMPHENOL - CONNECTOR
CARTRIDGES CARBON DIOXIDE CO2 10/BOX UN1013 Hazmat handling fees apply to 208608 not included in price.208608
FILTER PAPER 2.5in. DIA (6.35cm) 100/BOX 206056
Voltage transformer LV100 ROHS LEM
spare part ARV1.5-VU-L 120/12-B40A
VSG-4332-U-3-D024
Glyptal 1201G Red Alkyd Enamel Gallon; A15B17A
1201SC 1201 Spray Can, Red
HBM HBM 1-SK5/55 Ring collectors
"Precision Angular Position Transmitter PW70A in cast casing IP40
(with PW 1700Z04-096.008)"
ST52-N Ultra Sonic Nozzle Only
Barksdale "Barksdale UPA50434-012 0-16Bar,
output:4-20mA,Sealed copper pad "
"Barksdale UPA50434-190 0-400Bar,
output:4-20mA,Sealed copper pad"
JAHNS MTO-2-14-AVG125 Nr.158306 1台
FMC 3203043 UA050 0400 T*T** BNO 2500 CWP UNION ASSEMBLY 5 FIG 400, W/NITRILE O-RING LPT ENDS 2500 CWP (P.S: FMC 没有生产FIG 500 UNION, 因此提供了 最接近的FIG 400 款供选择)
3226733 O-RI-431 BNO 70 DURO O-RING, 5.225 ID X 0.275 CS, UNIFORM. NO.431, NITRILE 70 DURO PER ENGR SPEC E57020 MANUFACTURE TO ORDER ITEM (配套第一项 FIG 400 UNION 的密封)
3200612 UA040 0100 T*T** UNION ASSEMBLY 4 FIG 100 MALE SUB LPT X FEMALE SUB LPT 1000 CWP (FIG 100 4” UNION ASSEMBLY)
3200611 QUICK BEAT UNION, 3” FIG 100, 1000 PSI (FIG 100 3” UNION ASSEMBLY)
Magnetic Float Switch Type FLS-SA ARV 1,5"-VU-L120/12
美国进口AKRON阿密龙消防炮3443 数量10台
MM90758 HU-921-VDC-8 HUMID & TEMP SEMSOR 8 VDC
NOV SSW-30 HYD SPINNING WRENCH, 2.7/8" TO 9.1/2" RH&LH W/ VERTICAL POSITION SYSTEM
"volume PRAZISIONSDREHWIDERSTAND FSG PW 70/A/IP 40 13455023
1708Z03-096.013/01 2 "
BARKSDALE-BPT11FGA016 Barksdale BPT1000 Electronic Pressure Transducer
BARKSDALE-BPT11FGA400 Barksdale BPT1000 Electronic Pressure Transducer
Carmanah M650H Solar Powered 2, 3 NM LED Lantern基本款,不带开关,不带GPS同步装置等选配部件颜色:red/green/yellow/white/blue
带开关 with switch
带GPS同步装置 GPS Sync
安装螺栓包 Standard Bolt Kit
驱鸟装置 M650 Bird Deterrent
遥控编码器 IR Programmer
honeywell MIDAS
腔体组件/耐磨组件/5SV05F007T/LOWARA
机车运行保护模块|U33C|安太堡选煤厂材料线U33C机车保护模块 B450C;G.E;
"NIVOTEMP M-M12-PH104 200710040015
10001025910141499 MAX 1BAR/80℃
L=310 L1=260-NC 数量1个"
力士乐 HMV01.1E-W0075-A-07-NNNN
HMS01.1N-W0110-A-07-NNNN
ITT 110P44C3S
高低速油泵电机 MT-150GD01
VAL-TEX(沃泰斯)QS-1800A
AKRON MODEL 3443, MERCURY QUICK 消防炮
SQUARE-D 9002AW1
836TT251J Stock - ALLEN BRADLEY - PRESSURE
HBM 1 Pcs. K-T40FM-060R-MF-G-M-DU2-1-S Torque flange
Ingersoll Rand: ELEMENT SEP 6" TANK. 22517775
Midas? Extractive Transmitter (Generation 2) MIDAS-T-004
SQUARE-D 9002AW1
TAS 331DG DEIF -B211
GAMAK motor AGM714B
德国KRACHT克拉克齿轮泵 KF3/112F-10BP007DP1 1台
CSW 711-160
702-827
150-998
S/54-MF2-01
EPRO PR6423/010-140
PR6423/010-010/CON021\TSI
\PR6424/010-010/CON021
\PR6426/010-000+CON021/916-160
\MMS6210\TSNMMS6000\EPRO
\MMS3311/022-000\EPRO
HBM K-T40B-003R-MF-S-M-DU2-1-U
DEIF (GENUINE) TYPE: TAS331SG
ABB的ACS800-01-0011-3
SIR SRF600 8R0 5% 600W
FLIR T460红外热像仪
IME TA221 80/5A TA22150B800
TA221 100/5A TA22150C100
TM2IA34
FANN OF132-83
OF171-96-1
Handtool - Stiffy - 42inch Commodity Code 820110000 070XS42
Handtool - Stiffy - 50inch 070XS50
Handtool - Stiffy - 72inch 070XS72
AKRON Fire gun 3443 (monitor only)
RELIANCE P56H3883R
FANN 207122
207805
NWL 12816A
Q5203-AC
North Star PVM-3
STAFFA STAFFA HMB030/P/21 / SERIAL NO.: 00325303
Kracht Gearpump KF3/112F-10BP007DP1 + DKF 3 A 04
438020001 INVENSYS SIGNAL COND
Refurbished - MAX5041212F Todd Products
HOPPECKE 6V 170Ah @C10
西门子 A5E00059102 6AV3627-1QL01-0AX0
保尔 保尔电机Z 261607-35-2 A/188F4118 BS02-38H/DU04LA4-S/E003B7/SP
高压电器设备配件 NEMA1 风扇 RH50M-6DK 4I 1R
高压电器设备配件 ACS1016 过滤布 380*610*10
SWEENEY MOLYPASTE 503 (4 LB CAN)
SENSIRION TYPE:SFC4200 UAGUCV 质量流量控制器/AIR 2In/min 15-24v 1013 mbar[CS1241110001]
罗宾康 A5E03407403 1个
HDZ15 18升/桶
威格勒 AB-0003-1
FIS-6300-0101
SQUARE D 9002AW1
AB00031 WENGLOR - BOX
FIS63000101 WENGLOR - SCANNER
KUKA 117704
Mann+Hummel EIT-1372-36741 (ex. PF926)
Jumo MIDASC08
APP-ETH-PCU-C Applicom PCU2000ETH Ethernet TCP/IP 10/100
VAX Series High Pressure Axial Valve BVAXS2PO
POST GLOVER - JB160426-1 DB4D80-6K51-10400AA0 ( 4.8 ohm resistor)(6510 watt)T4F8R6K51
DEUTSCHMANN 编码器TA58-0360-GYE-ID
HU-921-1VDC-8,品牌MAMAC,3个
Ingersoll Rand 10 No LA421-EU
VEGAFLEX81 FX81ACETBFPXANAX
Calpeda TP100/A Peripheral Booster Pump 415V
DRUCK DPI 880 31D003041
倍福模块 规格:KL4034型号:2535043056
AMK变频器 规格:KWD2
LENZE 规格:LENZE GST05-2MVCK 071C42型号:0.55KW I=16.190 n1=1405 n2=86.8rpm B003 BFK458-08N
Calpeda TP100/A
applicom applicom PP-ETH-PCU / PCU2000ETH:Ethernet PCI-X Interface Card with 3.3 V / 5 V I/O Voltage Support
Atlas EP5PTX17R42-AT Atlas
Todd Products Power Supply (MAX-504-1212F) 230V 6A *USED*
Freistehende Notdusche FSP FSP洗眼器1212004Freistehende Notdusche FSP
TAKEX Takex FG4
TRICONEX 3805E
EATON-CUTLER HAMMER中压开关控制面板A21 CUTLER HAMMER型号A21
Faiveley法维莱 滤芯 集尘器温度传感器 TB21L2B6180 6个
作业风源空压机油滤 '0309060001 6个
作业风源空压机空滤 '0309050004 6个
空压机油滤 WD940 2个
空滤 2个
Mann PF926n Cartridge Oil/Hydraulic/Fuel Filter Mercedes-Benz Diesel,Volvo Penta
02 SENSOR LZA03-H01
"ASM - WS19KT-8000-PP24V-M4(A105572) POSI WIRE - Drawwire
sensor"
"ASM - CONN-DIN-12F-W (A117381)
mating connector"
WHEEL BLOCK DRS160-A45-B-O-B-H-W30
WHEEL BLOCK DRS160-A45-E-O-B-H-W30
D263 Diameters D263 SFC 23759
MISC HU-921-VDC-8
Vega Sensor FX81ACETBFPXANAX
Demag DRS 160-A45-B-O-B-H-W30
DRS 160-A45-E-O-B-H-W30
Original Ingersoll Rand LA421-EU
SA-3527-T SOLENOID
NGK IFR7F-4D
Heating element for bain marieP/no: BM1500/LU (220volt)
AEG AM56ZBA4
smitt 继电器-[规格:D8-U204-LQ,单刀双掷,8个触点] 数量40
smitt 继电器-[规格:D-U204-LQ,单刀双掷,4个触点] 数量100
waukesha 3003149857 (R) Sock Filter equivalent to 168660B
3003315505 (R) Air Filter Element equivalent to 169180K
INGERSOLL RAND filter element\INGERSOLL RAND\24242463\dryer
filter element\INGERSOLL RAND\24242471\dryer
Drain valve\INGERSOLL RAND\24335028\dryer
Control air filter element\INGERSOLL RAND\85565513\dryer
Control gas filter drain valve\INGERSOLL RAND\85566404\dryer
Control gas filter effect checking device\INGERSOLL RAND\705001-SP
waukesha P550614
瑞士SAIA-Burgess XCG9Z1 K1040
BEFELD 0 B6C-BS-60/3000 BEFELD
BEFELD 0 RB 5/10V BEFELD
BEFELD 0 RB 60/40V BEFELD
BEFELD 0 TPS 6 BEFELD
BEFELD 0 TSS 6L BEFELD
RS " 规格:M4*8图号:304-4902
"
NORGREN 规格:M/46116/M/160>005833图号:1003630 NB2252
SMC 规格:MY1B50G(SMC)
HANSHIN 规格:HSP 0320-2B
FESTO 规格:AEVULQ-50-20-P-A型号:2FCFEST AEVU-50-20-P
SpiraxSarco斯派莎克 规格:SPIRA/SARCO DP27 DN32 PN16/25
FESTO 规格:DSN-16-25-P/FESTO
NORGREN 规格:101251028
GRUNDFOS 型号:GRUNDFOS: UPA120
SMC 规格:AW30-03D
KLUBER 规格:KLUBER STABURAGS NBU 12(400g)
SMC 规格:SMC MY1B50G
GE 369-HI-R-M-0-0-0-E
GE 366A803G16
GAMESA WIND TIANJIN CO LTD GAMESA WIND TIANJIN CO LTD 43069999 000580 9010623
GP008132
AK9322 51312650
50045
apex 211B3654
台湾HIWIN 型号:HIWIN-LAS1-1-1-50-24GE
Pittman GM9234C262-R2 / 46445102, 2个
Versa Valves VSP-4502 Versa
BIK-3209
Rotem AC2000 pthermostat MB-04438-00
MDL43800000 (NSFP) INVENSYS - CONTROLLER
Ingersoll Rand: CAM (Superseded item # CV-12)30451488
GAMESA GAMESA接口板 50072
GAMESA制柜顶部通风风扇 50045
GAMESA偏航齿头GP009280
GAMESA多路温度转换模块 GP008132
GAMESA接口电路板 9010623
GAMESA液压站电机链接 50837
GAMESA液压站电机链接50836
GAMESA液压站电机链接50835
罐
圈
品牌BATTERY 电池PBS1-363 100件. BATTERY 备件?PBS1-363?
plus 普尔世 ML70.501
金凤 发电机定子电流监测模块 GENCURRENT 1个
机舱加速度模块 G-Sensor 1个
金凤系统过滤器 10μm 2个
金凤发电机转速测量模块 1个
plus 普尔世 ML70.501 1个
金凤变桨电机 AKOF 112 4.2 100001 4.5kW/53Hz 3×29V 1台
金凤过速模块 Overspeed 1个
SICK 规格:WT100-P4430材质特征值:【材质:其它】【SICK】【DC 10~30V】【<=0.1A】停产替代:WT100-2P4439
UNIVER 规格:AG-3003-20/62-24DV确认型号:AG-3003 含线圈DA-0051
Genesis 规格:genesis NP2.6-12
规格:ZZR-01
规格:SW-S7-049A材质特征值:【材质:其它】【13W】
Beckhoff 规格:KL4034型号:2535043056
AMK 规格:KWD2>46774<
Phoenix 规格:PHOENIX OPT-24DC/24DC/5 - 2982100 10的倍数起订
SIEMENS 规格:3RK1301-1GB00-1AA2材质特征值:【材质:其它】【SIEMENS】【4.5-6.3A】3RK1301-1GB00-1AA2
SIEMENS 规格:6EP1931-2DC21
FESTO 规格:SME-8-K-LED-24材质特征值:【材质:其它】【150 855 N613】(150855)SME-8-K-LED-24
LENZE 规格:LENZE GST05-2MVCK 071C42型号:0.55KW I=16.190 n1=1405 n2=86.8rpm B003 BFK458-08N
西屋 VL-12E 1600A 40KA DC220V P275MM H310
西屋 VL-12E 1250A 40KA DC220V P210 MM H310
水电站模块 . NDA5101
NDA1404B
DEIF (GENUINE) TAS331DG
MURR D 7570
Hydraulic Motor Staffa-KawasakiHMB030/P/FM/21
Takex FG4 Hi Temp Fibre Optic
FML-80-CI-LP-3EE-80/90CS-10-S1-D1 FLOW 8-80 L/MIN LIQUID, VISCOSITY 80/90 CS. CAST IRON BODY, LOW
Demag: Demag: Driving wheel, Nr.254477-76590044-05 DRS 160-A45-B-O-B-H-W30
DRS 160-A45-E-O-B-H-W30
Flygt 835857
BERNSTEIN 618.6189.287
TE IND art. nr. 9298627
MITSUBSHI ELECTRIC CORPORATION UMD-2A
Bernstein 618.6189.287 D-32457
MINCOThermal resistance S102952-PDPD-3S-120
FLENDER M100L4
M71M4
电机接线柱\5AP90S-6
电动执行装置\2SA5510-5CE10-4BB4-Z
ASCO电磁阀\YA2BA4522G00040\220VAC
YA2BB4522G00040 \220VAC
GE 42GE35AJ364R OEM
伊顿 87391-32-32/20411-52-32W×EHP500-32×1500/DCW+WP软管总成
20291-22-10/20511-30-10T×GH781-10×2450/DCW+WP软管总成
20511-42-16T/20511-36-16W×GH781-16×2200+WP软管总成
管夹1:THPG1-463
直通接头1:1D-42-RN
ABB MOTORS M3ARS132MD-2/4 3GAR138463-EDE001
1706 3GE110813P0263003
电机接线柱\5AP90S-6
GE CR104PTR20A0R
GE 218A4298P180
218A4298P100
9F60BDE001
GE fuse 9F60BDE001
22POTO10KTBW C3 - POTENTIOMETER
ABB ACS800-01-0100-3-D150-P901
EL3020
ECHESA齿轮箱 型号GE850PL
Versa Model No: BGG-3308-316-CC-ST-XX-D024 old model number was BGG-3308-316-CLL60-ST-XX-24DC
BGG-3308-316-CD-ST-XX-D024
Jamestown 45263A
93831A
Omron D5F-2B34C-Y
1LA7073-4AB10
1LE1001-1AB42-2AA4
斯瓦克离心机配件 "32634310550 Display , 2 X 16 for MI SWACO Centrifuge CD 518FH - STD, Make: Omron Part-No: NT2S-SF122B-EV2 NO
"
32634310551 Cable , Display NT2S for MI SWACO Centrifuge CD 518FH - STD, Make: Omron Part-No: NTSCN222 NO
32634310552 Cable , Adapter CPM2C for MI SWACO Centrifuge CD 518FH -STD, Make: Omron Part-No: CPM2C-CN111 NOS
32634310549 Micro Switch , for MI Swaco Centrifuge CD 518FH - STD, Make: Coelbo Part-No: LS5115 NOS
32634310438 Emergency Push Button, with Key Release for MI Swaco Centrifuge CD518FH,Make:coelbo Part-No: DP 8K NO
8NCLPT-5E 熔断芯 Eaton 十台.
美国千德乐 8040D10-SP1稠化仪 螺钉 P-2021
7716-SP1便携稠化仪 泵大修密封包 C09260
8040D10-SP1稠化仪 浆杯座销子 P-1454
8040D10-SP1稠化仪 O型圈 P-0061
8040D10-SP1稠化仪 专用内六角扳手 C08037
8040D10-SP1稠化仪 浆杯轴 08-0049
GAMAK GM3E 200 L 6B 245KG重
CLECO MPRO400GC
IFR / Aeroflex ATC601测试仪
PALL PALL压力开关 RC861CZ084HYR24DC 2只
51120 RMMDU 11/24 OUTPUT RELE’
P-Q CONTROLS M410-10-10
BRENTEK G-WDT24-T0.25-PD Serial No.070AA-001
BROWN PESTELL 减速机带电机 BHW102A-IEC-VAR05-03743EXD STOBER R17 VW1-5016-032
Manufacturer: SIEMENS | Part Number:42GE35AJ364R | Model: | Descrtption:
NAS B01386WA SLUDGE JUDGE, ULTRA, 3-PC. UNIT, 15 FT.,GLS No: W4061-1
PAULUHN 2634B-250
KB-6354-QQ KIT,VLV, 67CES,PCX,NL
B-6456-NN DIS VLV,60CRE,PCX,PRC,NL
B-6455-NN SUC VLV,60CRE,PCX,PRC,NL
A-0661 ELEMENT
A-0057 PISTON COLLAR, 2-1/2=8JG:MP
A-0487 UNL.PISTON RING, 3-1/2 O.D.
B-7032-K RBLD KIT,PIST ROD PKG ,1.125 REPLACED B-5285-K
B-5435-K RBLD KIT,WIPER PKG,1.125,NL,L2
A-15900 PISTON RING, 5-1/8JGA,PRC,NL
A-0501 V PACKING, UNL
109-01-55141 3X PLATE VLV 148CHT 5MM MT 820270X0435
406-8584 SPRING CLOSING 134R1 VLV8202 70X2018 REPLACED 14-01-30262
260-PS-2987 O-RING VT 260 6.75X.14 820270X1184
41-100078 GASKET VLV SEAT 148CHT/H148CHT 820270X2197
44-100078 GASKET VLV SEAT 148CHT/H148CHT 820270X2493
109-01-50478 3X PLATE VLV 127CGT 5MM MT 820270X0431
15-01-30262 SPRING VALVE YELLOW 820270X0800
357-PS-2987 O-RING, VT, 357, 5.88 X .21
15-100078 GASKET VLV SEAT 127CGT/H127CGT 820270X0804
35-100078 GASKET VLV SEAT 127CGT/H127CGT 820270X1438
53-PS-5804 DISC RUPTURE 1450/3700PSI YELL 820270Y3633
460-PS-2987 O-RING VT 460 16.00X.28 820270X2682
2071-100067 RING RIDER CR CA-TFE 13.50 2PC 820270X1018
455-PS-2987 O-RINGVT455 13.50X.28
2057-100067 RING RIDER CR CA-TFE 10.00 2PC 820270X1001
1-475179 RING SLINGER 665 820270X0790
1-104254 FLTR OIL SPINON NONBYPASSING 820270Y3217
4-PS-3519 VALVE CHECK LUBR .25NPT 820270X2704
EI 编码器 GHM9-11-T-9-6R-0005 11-30VDC 4只
ASM Positionssensoren MPM1B4-3C12P01600 20112208999
BHE MANUFACTURING RONNEBY SWEDEN DOC60-60H-F 32870 79571 43329593
GDS INTERNATIONAL WASHPIPE ASSEMBLY A100025
专用扣 CG-AJ531
防坠器 CGAC35IA
NBX-MX-SP-100
隔离开关操作电机:LS(LEROY SOMER) " 隔离开关操作电机:LS(LEROY SOMER),TYPE:MS56-85,
Induit:110V,8.7A,Puissance:0.65Kw,Vitesse:3500min-1,Service:S2-30 secondes"
WINTERTHUR 流量控制器 DC24V 25WCH-8409
品牌:HYDORING 油缸和密封总成 HD6020 PKP 50/36-120
火花塞|监视电极,可插入|制造商:WIEDEMANN|部件号:EZ 107350B
CARRIER 17-44727-00
17-40055-00
Continental-Hydraulics-VSD05M-1A-G-33L-B
68.44.02 Front Membrane Cell EESK 8,6/14/6,5/R-C AI, supply 10-30 mV, Output 4-20 mA,
199.14 Documentation
17-40056-02
HYDORlNG 型号:HD6020 PKP 50/36-120。 1套
油缸密封总成 HD6020 PKP 50/36-120 2套
SIEMENS 过压抑制器 5SD7424-1
FULLTECH UF 25GC12/AC120V
Q563-1016376-10-1010摇杆开关
PALL的压力开关RC771BZ084Z RC771BZ084Z
CANRIG盘根套组 A100025
LENZE EMZ9371BB
LENZE JK-KTY1/24型号:EL816527227材质特征值:【材质:塑料】【LENZE112I韩国】【24VAC/DC】【1 Wechsler 5A/30VDC】
西门子 6AV6 643-0CD01-1AX1
控制箱面板/C009227-001/PMD200C1/6T/11A/海诺威
Phenix Technologies 475-20 Phenix 475-20
MECHTEX motor MTSB4BGBP MECHTEX motor MTSB4BGBP
EV200AAANA TYCO
PKP "Like order no. 25878-1
Plastic variable area flowmeter
DS15.2.2.606L0.210.3.12.0"
"Like order no. 28825-3
All metal variable area flowmeter
DS25.1.335.2.319.2.1.0.00.SD"
VEM IE1K21R 200L 4MI TPM HW 211KG
ABB AZ20/.1.1.2.1.1.2.2.2.3.1.1.11.0.0.E./STD
MOOG SRA-73574
SMC OMRON PLC UNIT CP1E-NA20DR-A
ELECTRO PNEUMATIC PRESSURE REGULATOR ITV2050-01N31L-X69
Novellus 16-033931-00, Shower head
CP1ENA20DRA OMRON - CPU
095U3D300VACAA100190
KEB A1SM000-6400
BHE DOC60-60H-F 32870 79571 43329593
PNEUTRONICS 910-000046-037 (VSONC-5S11-VE-F0)
DC-Transformer Art. No 344.001 344-24-SD net weight: 230 gr / customs tariff no 85043121
Omron NT2S-SF122B-EV2
NTSCN222
CPM2C-CN111
型号、Xc4o36XLA一O9HQ240I,1100只
Xc3042一100卩G84M,250只
flsmidth minerals 3120005046
登福空压机零件号:QX100133油冷却器(风冷)250HP/300HP
艾讯 PE-6SD-R40 VER4.0
3800G HONEYWELL
K H EPE 差压开关\F4.2GW-02-00P\0~1000KPa
HBC 充电器/FLG105 230VAC 订货号:KFLG 105/230//
hansung的O圈 ORAR00008(4.47x1.78)
OR1000300(3x1)
OR1000200(2x1)
3M HF365/10
6008-SV1R AB模块
HTT 加热器96/FF40 (HTT)
控制器821H75S (HTT)
流量计(带变送器控制板) DOM-A10H R2 1 LH0 (KOBOLD)
流量计(带变送器控制板) DOM-A50HRB1L00 (KOBOLD)
EMA72 EATON CORPORATION
Burgmann MS01-ABS-MG1S15/65-G28-A1 Q1Q1PGG
VERSA CSG-4322-316-HT-XDAS-D024
TROMBETTA 684-2451-212
ICF-B-6124
ICS-D-32-N003
ICS-D-32-N015
ICF-B-6116
ICS-D-20-N015
ICFS-B-6120-N
ICS-D-20-N003 abb氧化锆加热组件 AZ200704
ICFS-B-6132-N
ICS-D-32-N003
KF28-92 KF SERIES PUMP 93LPM 210BAR 1000RPM 75KG
禹鼎摇控器 F21-2S
F21-2D
F21-4S
F21-4D
F21-E1
F21-E1B
F21-E2
F23-A++
F24-6S
F24-6D
F24-8S
F24-8D
F24-10S
F24-10D
F24-12S
F24-12D
F26-A1
F26-A2
F26-A3
F26-B1
F26-B2
F26-B3
F26-C1
F26-C2
F26-C3
CDL-RS
PDL-RS
F24-60
emg对中灯lic770
Burgmann MS37/90-G28
MG1S15/80-G60-A1
ANLOK公制全卡套 316-FF-6mm
HF36510 3M - CABLE
IC694DNM200 GE
Siemens ED63B060
42HF35AJ AC24 西门子接触器
"GEMS压力变送器 1200BGB4001A3UA G1/4外螺纹 温度-40-125 激励7-35DC 4-20MA 量程0-40BAR
"
ANLOK公制全卡套 316-FF-10mm
福伊特 弹性块 GR.300 每套10个 (2套)
耦合器阀组 EV2140NC
液压管总成 DN38S*42MP*7.5M
耦合器进水减压阀 DRV225
总进水压力传感器 CYD60-Y2-KC/5
Versa 电磁阀 CSG-4232-NX3-HT-PC-A240
CSG-4232-NS3-HT
Nord” 型号:SK 63 S/4 0L/HMS
ABB AZ20/112112113112100C/STD
ABB PH变送器 ABB PH变送器 AX460/1000C-AP100
NDC 105/13580-01SA红外水分仪上用的控制面板
200.0307 Aircushion type B30NC
BOLT AN6-7A
FP532-003 HOTSTART KIM-GLO 530W 240V 1.586
GE # 9T28B9702C4
Gould Sales<sales@gouldvalve.com> 1-1/4" Q4-3V, Air/Water 10-250psi, 24vdc
SIEMENS 40HP32AJ
XILINX Xc4o36XLA一O9HQ240I
XILINX Xc3042一100卩G84M
CP1ENA20DRA Omron
OMRON NB5Q-TW00B
VAL-TEX QS-1800A
TM710的彩色面板105/13580-01SA
Burgmann MS37/90-G28^ Q1Q1PGG
MG1S15/80-G60-A1^ Q1Q1PGG
HONEYWELL STD120-E2H-00000-S2
STD120-E2H-00000-S2
Mastervolt Lithium Ion Battery 24v/5000Wh ZMAS66025000
Westinghouse used IC695ETM001-EJ
IC31194G01+IC31197G01
IC695PSD040F
IC693BEM341-CD
IC695ETM001-EJ
IC31194G01+IC31197G01
GEFIC695PSD040
GEFIC695ETM001
MASTERVOLT 66025000 重130KG
辅助开关0209B4825P001LA08-412863-10513 SHALLCO
VAHLE 单极组合式滑触线地线 U10/25C-PE-VP 14319 VAHLE?
滑触线接头 UEV10 165006 VAHLE
滑触线地线接头 UEV10-PE-VP VAHLE
滑触线碳刷 DS2/40 168065 VAHLE
单极组合式滑触线 U10/25C 16706 VAHLE
SIKO MSK5000-0011一件
抽气泵 Buhler technologles Gmbh Harkortstr 29 D-40880 Ratingon Semple gas pump P 1 1 100100288 veilage:230V /50HZ Maiorial:PTFE/PVDF vartium max 70℃
42HF107829 siemens
Filterelement EM-60/3T, 603001
Filterelement EM-82/3T, 823001
HYDAC SB330-4A1/112A9-330A
SB330-10A1/112A9-330A
Hattink Thermo Parts C-174472700
C-174005500
C-174005602
HC-174472700
HC-174005500
HC-174005602
CONSILIUM EV-PP/TDT 2K 57 Heat detector 57 deg. C, 40215
EV-PP/RDO2/OA100 Optical smoke detector head
HC100 A2/IS IP67 Heat detector, IS, 5200047-00A
Norgren VAC030-S4-S4
FAW1242K (NSFP) TDK
Siemens M12161-24 is now a S29449
KONA Min-2
CALRAD 72-172
1470-2785-ND AC/DC DESKTOP ADAPTER 24V 48W
NB5Q-TW00B OMRON 5.6 INCH QVGA (320 X 234 PIXEL) TFT COLOUR TOUCH-SCREEN HMI WITH LED BACKLIGHT, 65,536 COLOURS
ROSEMOUNT ROSEMOUNT 644HAI1XA 一体化温度变送器
Siemens 3TK1142-0AU0
IFM PN3004
变桨变频器(带通讯板)COMBIVERF5-MULTI??1台
变桨电机-KEB??C240-01??1台
偏航变频器-KEB?COMBIVERT?F5-MULTI??15F5C1E-Y50A/E167544??2台
变桨变频器(带通讯板) 14F5M1E-Y00D
美国星技工业公司(NewTech Industrial Corporation) nt27b2pa-01 NewTech 5个
FL SWITCH SFN 8TX 2台
LRMA-QS-6
"ARTECH
" weighing sensor 80210-56Ton-125KLbs.
weighing sensor 80210-45Ton-100KLbs.
风扇104X215CA003
风扇 218A4787P1
阀芯阀杆组件 SN510351001
RACINE PSV PSS0 15ERM 51
F3-V10-IS6S-1C-20 \HPU-V150/B\美国VICKERS
VAL-TEX QS-1800A Viper-Foot Operated Manual Gun 25KG一个
FIREYE 95DSS2-1=
FIREYE 95DSS2-1CEX
bendix 229813
ARTECH weighing sensor 80210-125K
weighing sensor 80210-100K
IFM PN3094
SIGMA_22024 SIGMA 6-16HS heated centrifuge
SIGMA_Z0019 Swing-out rotor, 4 place for Sigma 6-16
Mastervolt Lithium Ion Battery 24v/5000Wh ZMAS66025000
Burgmann MG97S2/65-G60 Q1Q1PGG Burgmann
MG1/80-G28-A1 Q1Q1PGG Burgmann
MS30/90-00 EBPGG Burgmann
MS30/100-00 EBPGG Burgmann
MG1/90-G28-A1 Q1Q1PGG Burgmann
MS37/100-G28 Burgmann
MG1/45-G60-E2 Q1Q1PGG 9000 Burgmann
MG7/50-G25 AQ1PGG 023780000 Burgmann
MS01-ABS-MG1S15/65-G28-A1 Q1Q1PGG Burgmann
MS37/90-G28^ Q1Q1PGG Burgmann
MG1S15/80-G60-A1^ Q1Q1PGG Burgmann
EATON C25GNY8
0112835001 DANAHER CONTROLS - COUNTER
BENDIX 229813N
95DSS21 UTC FIRE & SECURITY COMPANY SCANNER
95DSS21CEX UTC FIRE & SECURITY COMPANY - SCANNER
EACH KQ10D110
KQ10D116
KQ10C110
KQE120C03
KQ10C316
KQ10C332
KQ10C116
KQ125SW3L
abb氧化锆加热组件 AZ200704
三星 CST51321-G06 三星振动传感器配件
CST51311-G02 三星振动传感器配件
CST51301-G04 三星振动传感器配件
PALL过滤芯 HC9601FDT8Z new part number HC9601FCT8Z
HC8314FAP39H
HC8314FCS39H
HC8314FKS39H new part number HC8314FCS39H
Parker CO40AA12N10
HC9601FDT8Z PALL Filter Replacement (sku: 100-6822)
HC8314FAS39H PALL HYDRAULIC Replacement (sku: 112-3132)
SBF-9601-8Z25V "Filter element 9601 series, 8"", 25 micron Viton seals. Replaces
9601-8-25UM, HC9601FKT8Z"
39QCLZ10V SAME AS HC8314FKS39H, 8315-39-12 CORELESS 39 IN 12 MICRON
FIREYE 60-2692 (1" NPT)
59-497 (price per foot)
35-127 (included in item #1)
60-1199 (-1) quoting 1" NPT
35-201 (1" NPT)
35-200 (NPT)
60-1664 (-3) quoting 1" NPT
IMHSS03,ABB的
Technoelectric 12003SM
E5SM-3201-23-H2-LB-ST-XX-D024 采购30只
Sandvik R390-054C5-54M Coromant
VERSA TXX-8533-H-HC-WS-D024
VSP-3301-31 USE VSP-3301
Square Shoulder Mill Cutter, R390-054C5-54M
阿尔斯通 P23 B00M151 5001619 39569/002
数显流量计PFMC7102-04-D smc
VAL-TEX 80-H-J
TF136100 GE 3PCS
TED113050 GE 3PCS
GE G102C10
G102C16
G102D06
G102D16
G102D20
G102D32
G103D06
G103D16
G103D20
G103D25
G103D40
G103D63
G102D06
G102D16
G102D20
G102D25
G102D32
G104D16
G102C20
G102C50
G102D25
G102D50
G103C16
G103C32
G103C40
G103C50
G103D32
G103D50
G104C32
G102C16
G104C16
G104C20
FDN36TD020ED
FDN36TD032ED
FDN36TD050ED
FDN36TD080GD
FDN36TD100GD
FDN36TD125GD
FDY306D160GD
FDY406D160GD
FEY306D250KF
FDN36TD025ED
FDN36TD040ED
G102C20
DCGE225/030
DCGE240/030
DCGE425/030
G102C16+DCGE225/030
G102C20+DCGE225/030
G104C16+DCGE425/030
G104C20+DCGE425/030
CL00A310TU
CL01A310TU
CL02A310TU
CL04A310MN
CL06A311MN
CL07A311MN
CL25A300TU
CL45A311MN
CL03A310MN
CL08A311MN
FDN36TD063ED
G102D10
RT1K
RT1L
RT1M
RT1N
RT1P
RT1S
RT1U
RT1V
RT1W
RT2G
FGY306D400LF
AST M63 30
AST M100 40
AST M100 30
AST M63 40
AST M80 40
AST M40 10
AST M40 20
AST M40 30
AST M40 40
AST M63 40
G102C50
G102D25
G102D50
G103D50
G104C32
FDN36TD080GD
FDN36TD125GD
FEN36TA125JF
FDY306D160GD
FDY306D160GD
FDY406D160GD
AST M100 30
EMG LS13.01
235251
Alicia 5928763 / 84136061 / 21 PSV PSSF 15ERM 52 ADJUSTABLE VANE PUMP
倍加福 浪涌保护器 K-LB-1.30G
K-LB-1.30G 带支架
浪涌保护器D-LB-1.C.123五件.
氧传感器\W303002-05
南油诺安 电路板\SNE4100B
苯传感器\PID900
检测传感器\ESD200/CH4
检测传感器\TS4000-CR-H2S
检测传感器\S104-3
离子室\PID900
电路板组件\PID900
检测传感器\SNE4100B-S
电路板\S104-3
电路板\TS4000-CR-H2S
电路板组件\TS4000-CR-CO
外置吸气泵\G201
一氧化碳传感器\TS4000-CR-CO
GFG 氨气传感器\EC35-C-NH3
延伸电缆\330130-045-01-05
电涡流探头\330901-00-36-05-02-00
CH-1290
美国LENOX LASER公司生产的SS-1/16-TUBE
AUTRONICA GT300C 2G10V 数量10个
BACHMANN "ATEX II2G Ex px IIC T4 Gb pressurization&purge control unit type F-351. as spare part to replace existing pressurization systems consist of pressure monitor F-101 and Control unit F-102 (TYPE: III B/E-28755 )
"
04-01-0180Mogensen - Clamping sleeve red / MW 12,5-110
04-01-0181Mogensen - Clamping sleeve yellow / MW 4,5-11,2
06-50-0405Mogensen - GFK-Cover 15X
06-50-0400Mogensen - GFK-Cover 10X
Fairchild 10292
Grove Gear/Electra Gear Speed Reducer EL-FLMQ-821-7.5-RR-56
Eaton C25GNY8
47062500 6" GAUGE 16.000 PSI
47062508 6" GAUGE 16.000 PSI
ELB ATEX II2G Ex px IIC T4 Gb (ex.F-101 + F-102)
Westinghouse 1X00093G42 switchboarD
Pratissoli KF 28
Grove GEAR EL-FLMQ-821-7.5-RR-56 EL8215139.00 EL8215139.00
HS45FAYXX8PFA4Z AVTRON encoder HS45FAYXX8PFA4Z
ALSTOM ALSTOM P123 B00M151 5001619 39569/002升级替代型号:P123B00Z112CEO
077PB11G 5只 GE
Electrodrives D132S GT/BC/1606/1251
MDEL MLT2-IRIR
86 UNITS DETECTOR DE PROXIMIDAD CON CABLE 10 30 VDC
LA MAXIMO 400 mA ( CR PULSOTRONIC 9962-1533)
37 UNITS DETECTOR DE PROXIMIDAD SN 40mm, 10
30 VDC; LA MAXIMO 400 mA, NPN (CR 9863-3500
PULSOTRONIC)
震动电机SG3X-44-18-460/480-6-001供应
震动电机SG3X-44-18-460/480-6-001供应 报价 厂家
Alrflex 508725动摩擦盘
伊顿钻机动盘刹车片508725
伊顿WCB324水冷式辅助刹车24"动摩擦盘508725
EATON 508725动摩擦盘
ASCO WSNF8327B102MO
HALLIBURTON 黄油抢\70.24776/100001778\旋塞阀 供应
LAMP\12V 1.9A\TIDELAND\185.1048\NAVIGATION/03-9100 供应
Black Toner Cartridge 600-1360 供应 加拿大isys 600-1360黑色墨盒
Cyan Toner Cartridge 600-1362 销售 加拿大isys 600-1362青色硒鼓
Magenta Toner Cartridge 600-1364 价格 加拿大isys 600-1364品红硒鼓
Yellow Toner Cartridge 600-1366 厂家 加拿大isys 600-1366黄色墨盒
Black Image Drum 600-1370 低价供应 加拿大isys 600-1370黑色图像鼓
Cyan Image Drum 600-1372 厂家直销 加拿大isys 600-1372青色图像鼓
Magenta Image Drum 600-1374 优势价 加拿大isys 600-1374品红图像鼓
Yellow Image Drum 600-1376 代销售 加拿大isys 600-1376黄色图像鼓
Transfer Belt 600-1380 询价 加拿大isys 600-1380传送带
Fuser 230V 600-1382
Fanfold Paper CL-85FF5500HWHB
浮球式位面開關 "JO-BELL" M/N:CB-800-7A/4X-GZA3WH
MMC 油水界面仪D2562-1-C18
美国JET-LUBE润滑油 JET-LUBE PN:10115
SWEPCO 101 MOLY GREASE VALVE SEALENT 710194-02
万能转换开关\LW5B-16-F/1\380V\液压站/HYZ250B
LAMP\12V 1.9A\TIDELAND\185.1048/03-9100导航灯
注脂枪维 修包Val-tex1400 cmahometpom 套
注脂枪维 修包Val-tex1000-31Bcmahometpom 套
SWEPCO 101 MOLY GREASE VALVE SEALENT 710194-02
可燃气体检测报警仪\4543230\0~100%LEL\0.5\DC24V
滤波电容器\0.4kV\60Hz\6000uF
NUT\M16-1.5 GRADE 10.9\1305040
德国vatec-Maschinenbau ELB45
NASH-ELMO BENELUX修 理包
美国AKRON消防水炮3443型
美国AKRON消防水炮3125型
DAMCOS 液压控制阀160L8052
DAMCOS 液压控制阀160L8064
安全带/SALA 1111622/GB 6095-2009
美国DELTROL SV20B梭阀
美国DELTROL PICB20S液控单向阀
JET-LUBE抗咬合润滑油KOPR-KOTE 10115
阀板油 710194-02 阀密封胶
3D instruments 压力表
量程:2bar P/N25104-48B24 ISB
量程:280bar P/N25504-34B24 ISB
Redington 计数(时)器 型号:720-0003
英格索兰 隔膜泵
6661A3-3EB-C
PD15P-YPS-PAA
KEM TD-01.0 01124125
KEM ZHM 02/1 ST.D.T 01537125
KEM ZHM 01 ST.D.T 01525125
TESCO 500ECT 内防喷器(钻机顶驱装置配件)720475
CCPZ-I双向直板清管器 Bi-direction pig
II型光体泡沫球 Foam pig
CAVOTEC N6-01RP电位器
力度克 MA90 C S2 NO U2 0 0 SVF 马达
E2S 声光报警器 BEXCTS110-05
E2S 声光报警器 BEXDCTS110-05
HALLIBURTON CO US黄油枪
HALLIBURTON CO US高压黄油
HALLIBURTON CO US黄油嘴
猫牌3535高压泵配件瓷柱塞
猫牌3535高压泵配用调压阀7022
瓷柱塞接杆用于3535高压泵
HIMA黑马耦合板电池/CR-1/-2AA-CD F7131电池
Trioving LOCKS 船用锁 5312/8
VARCO TDS-8SA顶驱钻井系统 CONNECTOR,ELEMENT 连接器
VARCO TDS-8SA顶驱钻井系统 ELEMENT,FILTER 过滤器
samin av21-02-5-a-kr
METTLER-TOLEDO 传感器 SB-5A
NOV VARCO顶驱动力53805-A
703-1440-06电路板
压力表组\BM2-6-DS-R22 /瑞士威科REFCO 双表头加氟表组
机械锁 防火门锁\5316/8\不锈钢\TRIOVING
美国TFT移动式自摆炮LMP80-5000
德国黑马HIMA 模块H41q-MS
GE 34W灯管 F34CW-RS-WM-ECO
GE 20W灯管 F20T12-CW
PARKER KITTIWAKE的燃油取样器 FG-K1-125-KW
德国vatec-Maschinenbau FBP2388泵
德国vatec-Maschinenbau 132M/4B-11电机
Jo-bell浮筒式物位开关WCB隔爆型CB-300-7-EAZWH
MEDC DB3B/XB15户外闪光灯 24VDC COMBI UNIT
Miwaco振动筛压条
GASKET, SET, CROSBY GROUP INC, 200286, 316 STAINLESS STEEL,ANDERSON GREENWOOD, FOR RELEF VLV
海德派尼克 8050
Super GTM EX-38-15-380/400-5-001
arox洗衣机 ARC40 AC220/DC12. AL12031ME
Azbil调压阀
MMC RSD-F100-4寸甲板阀
AUTRONICA BD-501/EX感温探测器
挪威PLT抛绳器R-230
CEAG GHG 273 2000 R0003
SALA安全绳11MM 1270158
密封圈PS-SEAL,60*80*10 12/10 MEC04-10301
DCS-R\VARCO\2620
德国黑马HIMA模块H4007
MMC氧传感器电池A2615-17
边界灯\SM87LU3AB220BN2NW?\IP67\ExdⅡCT5\220V\40WSM87LU3AB220BN2NW 蓝色Medc
边界灯\SM87LU3AB220YN2NW\IP67\ExdⅡCT5\220V\40WSM87LU3AB220YN2NW 黄色Medc
Val-tex硫化钼阀门润滑油2000-S-P
配件号:0000-9056-01\配件规格型号:1092547\配件生产厂家:ROSS HILL CO U.S.A
BVV81B3KM-03ZP-X绞车操作手柄Gessmann
SOLO-823-001一套 (包含Solo 100 玻璃纤维伸缩杆4.5m Solo 101 玻璃纤维延伸杆1.13m Solo 200 探测器移除重装装置 Solo 330 岩区气溶胶测试装置 Solo 461 无绳感温探测器测试装置 Solo 610 便携包)
英格索兰ARO调压阀127122-000
aviteq 电机 mve50
HYDROTECHNIK压力传感器3403-15-D5.37
德国SMAG 00025986
德国SMAG 00022524
BZ28-2S CEP超声波滤器装置 /CEP-X-4702 /原普通篮式滤器升级为超声波防海生物滤器,CEP-X-4702
BETE 喷嘴 3/4 TF32FC 喷雾夹角:120° 喷雾类型:实心锥 接口:3/4"NPT外牙 材质:UPVC 流体参数:95.7LPM(1bar)~135LPM(2bar)
索耐MPI-525可燃气探头 IR2100报警系统
丹麦进口DAMCOS蝶阀
CH00633
CH00634
CH00635
CH00632
CH00879
CH00880
隔爆差压表带差压开关 Mid-West 240SC-02-0(RAA)0-500mb
高压清洗机\KJ-1590Ⅱ\RIDGID
LUBRICANT IR ULTRA COOLANT 38459582
德国elan按钮开关安全继电器EF 303.1
VAL-TEX的1800的脚踏式滑脂加注器
ELECTRIC WATER BOILEK 开水机 DF-10B
AVITEQ振动器KF0.5-1
挪威SKIPPER GDS101 导航测深仪
Argus4HR320红外热像仪
高压柱塞泵 SCP-047R-N-DL4-L35-SOS-0775281
高压柱塞泵组SC012/1LG0130-4AA16 40MPA 泵头
压载阀位指示限位开关 160B4023 DAMCOS
TESCO 5017888钻机顶驱装置配件
显示屏\BS-1108\AUTRONICA\116-BS-1108\火灾寻址盘 AUTRONICA
DUAL RTD SENSOR\MTS-L35166P01\MAXIMUM TURBINE SUPPORT\00422-1\GAS TURBINE
WILDEN隔膜泵 HP800 材质球墨铸铁 591617
电缆固定绑扎带AE 434 type 316 SS,厂家:BAND-IT size1/2";25m per box带塑料保护层;AE4349
AE 454 type 316 SS,厂家:BAND-IT size1/2";100pcs/box ;,AE4549
AE 435 type 316 SS,厂家:BAND-IT size5/8";25m per box带塑料保护层;AE4359
AE 455 type 316 SS,厂家:BAND-IT size5/8";100pcs/box ,AE455
三菱压缩机 HNB71FA-YJE
BWP20-08 AUTONICS 区域传感器 AREA SENSOR
ZIEHL-ABEGG(施乐百)风机
QK10A-2EM.48.FK, motor type:92-50-2,article no:110179
AUTRONICA火焰探测器BG-201
PCM泵传动皮带CW-B37-1120L\1167LW-8229-2-1-0
TFT 型号:BER-HT1501
TFT 型号:BGH-HT50-DS
TFT 型号:BGH-HT150-PD
德国FHF HPW1124VDC警报喇叭
ZAPI 交流控制器FZ5238-INV AC-1 36-48/220 SSL C/FLASH
733 润滑密封脂 Serck Audco733润滑密封脂
960 润滑密封脂 Serck Audco960润滑密封脂
HYDROTECHNIK比例阀SDVPRB.330-PT-FY-6-2
障碍灯灯泡\24V HPL20 RED\20W 厂家:ORGA 接口形式插口
厂家部件号:34S02420 BIAX 18W FOR HSL18
单边带 品牌:SAILOR 型号:6350 购买整套单边带,清单如下:SAILOR6350 MF/HF 500W 主机 SAILOR 6301 控制单元SAILOR 6364 收发主机单元 SAILOR 6383 天调单元 SAILOR 6080 电源 AC MARINE KUM803 天线
AVITEQ电机UVG38X
APPLETON明插座及NFB耐压防爆型插座CPH-6023BC
口环\POMPE GARBAINO S.P.A.\1521LBA8R8R01A\主冷却海水泵/MU250-500V
IMPELLER;POS NO.: 2200;SPARE CODE: 2200UBA8R4500A;GARBARINO;PUMP TYPE: MU250-500;SERIAL NO.:33737/33738/33739
MECHANIC SEAL\POMPE GARBAINO S.P.A.\4200BB65MG121QQVGG\主冷却海水泵/MU 250-500V
STATOR\POMPE GARBARINO S.P.A\601\舱底日用泵/10-6L BN/A1-A7-A7-FO-GA
DOUBLE ROW ANGULAR CONTACT BALL BEARING;POS NO.: 3017;SPARE CODE: 3017-3313;GARBARINO;PUMP TYPE: MU250-500;SERIAL
NOV 接线端子 81882
NOV 风机 77899
NOV 线板 78751
NOV 保护单元 78046-1
压力调节阀\TMC\NT0750\COMPRESSOR\M160-13 EWNA 505 590 10
吸顶扬声器\SAFE-10P(T)\10W\定压70V\DNH
大电流接地电阻测试仪MRU-120波兰索耐
VAL -TEX脚踏式液压注脂枪QS-1800A-K
立管压力传感器胶杯\E40-1\M/D TOTCO\钻井仪表
DAMCOS 压载系统液位传感器MAS2622-H30-11-1-2P
美国Farris(阀帝),TYPE:27CC13-M20S4,SIZEANDORIFICE:二分之一*1-C,SETPRESS:1.7MPadg,BACKPRESS:0MPadg,COLDDIFFTEST.PRESS:1.7MPadg,含进出口接头
FANN 21200 数显极压润滑仪
710194-02阀板油SWEPCO
Wax tape蜡磁带4“*9 宽100mm*长2.74m*厚2.0mm TRENTON
TRENTON Primer(White)
HALLIBURTON 黄油 7031058
冰熊 RL68H 机油
5492642 光钎接头
MOTOR CONTROLLER ACCESSORY\150-NFS
LUBRICANT\MARTIN DECKER TOTCO W15 马丁代克
发动机组除油剂 YWGA-1MSC 3.78升/桶 ZEP
环保型除锈剂 XWGA-1RR 3.78升/桶 ZEP
机械除油、除胶剂 Y00Z-20BO 591ml/听 ZEP
机械除油清洗剂 YWQU-1CC 591ml/瓶 ZEP
即用型擦拭剂 QQQU-1WV 946ML/听 ZEP
金属零部件清洗剂 YWGA-1AO 3.78升/桶 ZEP
浓缩环保多功能清洗剂\ZEP BLA0-001\液体 ZEP
顽固阻塞疏通剂 QQCDOT 908克/瓶 ZEP
烟雾测试剂\SOLO A3-001 SOLO
液体手套 QQZGOT 251ml/瓶 ZEP
仪表油\TOTOC W8 "马丁代克"
JISKOOT采样接收机18L\3J-43-0530-00
OVEN RESISTANCE 加热元件 RF1
SELECT SWITCH 选择开关 S1
THERMAL RALAY 热继电器 FR1
CONTACTOR 接触器 KM1
HEATING ELEMENT 加热元件 R1
SWITCH 开关 SE
FUSE 保险 F3
FUSE 保险 F4
ELEKTROMAGNETIC SWITCH 选择开关 C1
HEAT DETECTOR 热探头 116-BDH-500
SMOKE DETECTOR 火灾探头 116-BHH-500
HEAT DETECTOR 热探头 BD-501/EX
SMOKE DETECTOR 火灾探头 116-BHH-500/EX
FLAMMABLE GAS DETECTO 可燃气体探头 型号:IR2100
FLAMMABLE GAS DETECTOR 可燃气体探头 型号:S4000CH
H2S DETECTOR H2S探头 型号:TS4000
加热丝 1912069115
PRESSURE SWITCH 压力开关 PH14-1194-S009
PRESSURE SWITCH 压力开关 PH14-0027-A10-ASB#A03
LIMIT SWITCH 限位开关 PH14-1194-S003
CONTACTOR 接触器 PH14-1194-P022
SENSOR PROXIMITY 接近传感器 PH14-1194-S004
RELAY 继电器 RXM4AB1P7
RELAY 继电器 RXM4AB1BD
FUSE 保险 99200-16513
PRESSURE TRANSMITTER 压力传感器 20383992
PRESSURE TRANSMITTER(0-200psi) 压力传感器 100548969-003
PRESSURE TRANSMITTER 压力传感器 20383991
PRESSURE TRANSMITTER(0-3000psi) 压力传感器 10548969-008
LIMIT SWITCH 限位开关 11391247-001
POSTTTION TRANSMITTER 位置传感器 20394391
TEMPERATURE TRANSMITTER 温度传感器 51021901
SELECTOR SWITCH 选择开关 11387842-001
AROX AWP-25SS沸水机
MMC UTI(型号:D-2401-2) 探头
MMC UTI(型号:D-2401-2) 油尺35米
MMC UTI(型号:D-2401-2) 油尺40米
COOPER库伯航空障碍灯L-810 OX2LFSR/120
MEDC声光报警器XB13/DB12
Outdoor Explosionproof Loudspeaker(室外防爆喇叭)Model:DB10 15Watt,规格15W 100V,入口1×M20,防爆等级:ExdⅡBT4,品牌:MEDC
BUKH 144柴油机燃油滤芯610D0201
BUKH 144柴油机润滑油滤芯610J0050
JISKOOT 取样接收器pr-53
EVAC 液位开关 6549127
EVAC 液位开关 5430612
|